Display: Delivery guide of SP unit is not mounted. Check if the guide is mounted properly and press OK.
Description: While the spectrophotometer up-down unit upper detection sensor and spectrophotometer top cover open/closed detection sensor are detecting, the interlock switch remains OFF.
Remedy: 1. Mount delivery guide. 2. Replace the spectrophotometer unit PCB. 3. Replace spectrophotometer updown unit upper detection sensor.
Display: SP unit up and down cover is open. Close it and press OK
Description: Spectrophotometer top cover open/closed detection sensor won't respond.
Remedy: 1. Close spectrophotometer top cover. 2. Replace spectrophotometer top cover open/closed detection sensor. 3. Replace the spectrophotometer unit PCB.
Display: Colorimetric readout error. Please press OK and execute color measuring again.
Description: When executing color measuring, the spectrophotometer sensor returned a value other than predetermined value was returned.
Remedy: 1. Operate paper feed adjustment. 2. Change the patch size to large. 3. Printer support (In case of printing failure). 4. Replace spectrophotometer sensor