  • Code: E141-4046
  • Description: Recovery part revolutions reaching 50,000 cycles or more Recovery part operations have reached a predetermined count.
  • Remedy: Check the parts counter and replace required parts. (Replacement of the parts coming to the end of their useful lives is recommended.) Initialize the counter for the replacement unit mounted. The iPF5000/500/600 have a counter problem fixed. Identify the firmware version and start in download mode to upgrade the firmware to Ver.1.13 or later from any earlier release.
  • Code: E144-4047
  • Description: Carriage count error Supply part operations have reached a predetermined count.
  • Remedy: Check the parts counter and replace the target unit or Refresh Service Kit. Initialize the parts counter for the target unit after the replacement.
  • Code: E144-4048
  • Description: Non-discharging nozzles on initial filling An unallowable number of nondischarging nozzles have been detected at the completion of initial filling.
  • Remedy:
  • Code: E144-404F
  • Description: Pump revolutions full The number of HP pre-ejection pump revolution has reached the defined value.
  • Remedy: Clear the counter in service mode after having replaced the HP pre-ejection tray unit.
  • Code: E146-4001
  • Description: Borderless/flow pre-ejection/mist recovery count full
  • Remedy: Check the parts counter and replace the target unit or Refresh Service Kit. Initialize the parts counter for the target unit after the replacement.
  • Code: E161-403E
  • Description: Head abnormal temperature rise (printhead 1 (R), or A model) Either of the two Di sensors maintained for each printhead chip (color-specific) has been detected at 120 degrees C or higher or -10 degrees C or lower.
  • Remedy:
  • Code: E161-403F
  • Description: Head abnormal temperature rise (printhead 2 (L)) Either of the two Di sensors maintained for each printhead chip (color-specific) has been detected at 120 degrees C or higher or -10 degrees C or lower.
  • Remedy:
  • Code: E161-4050
  • Description: Non-ejection detection error The timing of "ink priming sequence" is fallowing. -At installation of a new model printer -At reinstallation after the second transportation. -At replacement of the printhead
  • Remedy: