Description: EEPROM error of the CCD unit
An error has occurred at power-on.
Remedy: 1. Disconnect and then connect the flexible cable(CCD unit- Reader Controller PCB (UN4)). 2. Replace the flexible cable. 3. Replace the CCD unit.
Description: EEPROM error of the CCD unit
An error has occurred during write operation
Remedy: 1. Disconnect and then connect the flexible cable(CCD unit- Reader Controller PCB (UN4)). 2. Replace the flexible cable. 3. Replace the CCD unit.
Description: EEPROM error of the CCD unit
An error has occurred during read operation following write operation.
Remedy: 1. Disconnect and then connect the flexible cable(CCD unit- Reader Controller PCB (UN4)). 2. Replace the flexible cable. 3. Replace the CCD unit.
Description: Error in Zero Cross
Zero Cross failed to be detected for 500ms or more while the relay was ON. * The same condition is detected after the error retry is performed.
Remedy: 1. Check the Connectors. (J113/J202) 2. Replace the Power supply PCB (UN1). 3. Replace the DC Controller PCB (UN2).
Description: Reading unit communication error
Reading error after writing.
Remedy: 1. Disconnect and then connect the flexible cable(Reader Controller PCB (UN4)-Main Controller PCB 2 (UN14)). 2. Disconnect and then connect the flexible cable(CCD unit- Main Controller PCB 2 (UN14)). 3. Replace the flexible cable. 4. Replace the Reader Controller PCB (UN4). 5. Replace the Main Controller PCB 2 (UN14).