Description: Erroneous communication with finisher (reception data error)
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.
Code: E713-0021
Description: Erroneous communication with finisher (reception time out error)
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.
Code: E713-0022
Description: Erroneous communication with finisher (reception data error)
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.
Code: E716-0000
Description: Erroneous communication with cassette pedestal
After the presence of a cassette pedestal has been detected, the communication fails to be normal for 5 sec.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Cassette Pedestal Driver PCB.
Code: E717-0001
Description: Communication error with the NE Controller
Error when the NE Controller is started. The NE Controller which was connected before turning OFF the power is not connected at power-on.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
Code: E717-0002
Description: Communication error with the NE Controller
IPC error at NE Controller operation. Open circuit of IPC, unable to recover the IPC communication.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
Code: E719-0001
Description: Error in coin manager
Error when the coin manager is started. The coin manager which was connected before turning OFF the power is not connected at power-on.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
Code: E719-0002
Description: Error in coin manager
IPC error at coin manager operation. Open circuit of IPC, unable to recover the IPC communication. When open circuit of the pickup/delivery signal cable is detected. Invalid connection is detected.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.