Description: Horizontal registration sensor 2 error
The voltage of the light received is 2.5 V or less even when the light emitting duty of the horizontal registration sensor 2 (LED2,PTR2) has been increased to 66% or more.
Remedy: 1. The wiring between the LED PCB/photosensor PCB and punch controller PCB is faulty. 2. The LED PCB and photosensor PCB is faulty. 3. The punch controller PCB is faulty. 4. The finisher controller PCB is faulty.
Description: Horizontal registration sensor 2 error
The voltage of the light received is 2.0 V or more even when the light emitting duty of the horizontal registration sensor 2 (LED2,PTR2) has been decreased to 0%.
Remedy: 1. The LED PCB and photosensor PCB is faulty. 2. The punch controller PCB is faulty. 3. The finisher controller PCB is faulty.
Description: Horizontal registration sensor 3 error
The voltage of the light received is 2.5 V or less even when the light emitting duty of the horizontal registration sensor 3 (LED3,PTR3) has been increased to 66% or more.
Remedy: 1. The wiring between the LED PCB/photosensor PCB and punch controller PCB is faulty. 2. The LED PCB and photosensor PCB is faulty. 3. The punch controller PCB is faulty. 4. The finisher controller PCB is faulty.
Description: Horizontal registration sensor 3 error
The voltage of the light received is 2.0 V or more even when the light emitting duty of the horizontal registration sensor 3 (LED3,PTR3) has been decreased to 0%.
Remedy: 1. The LED PCB and photosensor PCB is faulty. 2. The punch controller PCB is faulty. 3. The finisher controller PCB is faulty.
Description: Horizontal registration sensor 4 error
The voltage of the light received is 2.5 V or less even when the light emitting duty of the horizontal registration sensor 4 (LED4,PTR4) has been increased to 66% or more.
Remedy: 1. The wiring between the LED PCB/photosensor PCB and punch controller PCB is faulty. 2. The LED PCB and photosensor PCB is faulty. 3. The punch controller PCB is faulty. 4. The finisher controller PCB is faulty.
Description: Horizontal registration sensor 4 error
The voltage of the light received is 2.0 V or more even when the light emitting duty of the horizontal registration sensor 4 (LED4,PTR4) has been decreased to 0%.
Remedy: 1. The LED PCB and photosensor PCB is faulty. 2. The punch controller PCB is faulty. 3. The finisher controller PCB is faulty.
Description: Horizontal registration home position error
At time of horizontal registration motor initialization, the punch slide unit does not leave the horizontal home position sensor even when it has been driven for the specified distance.
Remedy: 1. The horizontal registration home position (PI61) is faulty. 2. The wiring between the punch controller PCB and sensor is faulty. 3. The horizontal registration mechanism is faulty. 4. The horizontal registration motor (M62) is faulty. 5. The punch controller PCB is faulty. 6. The finisher controller PCB is faulty.
Description: Horizontal registration home position error
At time of horizontal registration motor initialization, the punch slide unit does not return to the horizontal registration home position sensor even when the unit has been driven for the specified distance.
Remedy: 1. The horizontal registration home position (PI61) is faulty. 2. The wiring between the punch controller PCB and sensor is faulty. 3. The horizontal registration mechanism is faulty. 4. The horizontal registration motor (M62) is faulty. 5. The punch controller PCB is faulty. 6. The finisher controller PCB is faulty
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.