Code: E000-0001

Description: Fixing temperature abnormal rise
The temperature detected by the main thermistor does not rise to the specified value during startup control.
Remedy: 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR; and then turn OFF and then ON the power. 2. Check connection of the Connectors (Thermistor Connector: J2063/J2510/J214, AC Connector: J105). 3. Replace the Fixing Main Thermistor (Film Unit). 4. Replace the Fixing Main Unit. 5. Replace the DC Controller PCB (UN2).

Code: E001-0000

Description: Fixing unit temperature rise detection
The reading of the main thermistor is 250 deg C or more continuously for 200 msec.
Remedy: 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR; and then turn OFF and then ON the power. 2. Check connection of the Connectors (Thermistor Connector: J2063/J2510/J214, AC Connector: J105). 3. Replace the Fixing Main Thermistor (Film Unit). 4. Replace the Fixing Main Unit. 5. Replace the DC Controller PCB (UN2).

Code: E001-0001

Description: Fixing unit temperature rise detection
The hardware circuit detects overheating of the main or sub thermistor for 30 msec.
Remedy: 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR; and then turn OFF and then ON the power. 2. Replace the DC Controller PCB (UN2).

Code: E001-0002

Description: Fixing unit temperature rise detection
The reading of the sub thermistor is 295 deg C or more continuously for 200 msec.
Remedy: 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR; and then turn OFF and then ON the power. 2. Check connection of the Connectors (Thermistor Connector: J2063/J2510/J214, AC Connector: J105). 3. Replace the Fixing Main Thermistor (Film Unit). 4. Replace the Fixing Main Unit. 5. Replace the DC Controller PCB (UN2).

Code: E002-0000

Description: Fixing unit temperature insufficient rise
1. The reading of the main thermistor is less than 115 deg C continuously for 400 msec 2.5 sec after it has indicated 100 deg C. 2. The reading of the main thermistor is less than 150 deg C continuously for 400 msec 1.3 sec after it has indicated 140 deg C.
Remedy: 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR; and then turn OFF and then ON the power. 2. Check connection of the Connectors (Thermistor Connector: J2063/J2510/J214, AC Connector: J105). 3. Replace the Fixing Main Thermistor (Film Unit). 4. Replace the Fixing Main Unit. 5. Replace the DC Controller PCB (UN2).

Code: E003-0000

Description: Low fixing temperature detection after standby
The reading of the main thermistor is less than 100 deg C continuously for 200 msec or more.
Remedy: 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR; and then turn OFF and then ON the power. 2. Check connection of the Connectors (Thermistor Connector: J2063/J2510/J214, AC Connector: J105). 3. Replace the Fixing Main Thermistor (Film Unit). 4. Replace the Fixing Main Unit. 5. Replace the DC Controller PCB (UN2).

Code: E004-0000

Description: Thermistor disconnection detection error
When disconnection is detected with connector for 30 sec continuously.
Remedy: 1. Check connection of the Connector (J2063/J2510/J214). 2. Replace the Film Unit. 3. Replace the Fixing Main Unit. 4. Replace the DC Controller PCB (UN2).

Code: E010-0001

Description: Unstable rotation of the Main Motor (M1)
Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec.
Remedy: 1. Check connection of the Connector (J2002/J2255/J203). 2. Replace the Main Motor (M1). 3. Replace the DC Controller PCB (UN2).