Description: PDL communication error
No reply from PDL. Due to failure of Subbootable, or no existence, there is no reply from PDL.
Remedy: 1. PDL reset processing. 2. Turn OFF and then ON the power. 3. Check the connection of the Main Controller PCB. 4. Reinstall the firmware. 5. Replace the Main Controller PCB.
Description: Reader communication error
Negotiation failure.
Remedy: 1. Check the connection of the Connector with the Reader. 2. Check the power of the Reader (check if the initialization operation is executed at startup). 3. Replace the Reader Controller PCB and the Main Controller PCB.
Description: Reader communication error
Communication error.
Remedy: 1. Check the connection of the Connector with the Reader. 2. Check the power of the Reader (check if the initialization operation is executed at startup). 3. Replace the Reader Controller PCB and the Main Controller PCB.
Description: Reader communication error
Unable to detect Vsync from the Reader Controller although 2 minutes have passed after the completion of register setting of the Main Controller.
Remedy: 1. Check the connection of the Connector with the Reader. 2. Check the power of the Reader (check if the initialization operation is executed at startup). 3. Replace the Reader Controller PCB and the Main Controller PCB.
Description: Reader communication error
Communication error
Remedy: 1. Check the connection of the Connector with the Reader. 2. Check the power of the Reader (check if the initialization operation is executed at startup). 3. Replace the Reader Controller PCB and the Main Controller PCB.