Description: Front aligning plate home position error
The aligning plate does not return to aligning plate front home position sensor when the alignment plate front motor has been driven for 4 seconds.
Remedy: 1. The front aligning plate home position sensor (PI106) is faulty. 2. The wiring between the finisher controller PCB and front aligning plate motor is faulty. 3. The front aligning plate is faulty. 4. The front aligning plate motor (M103) is faulty. 5. The finisher controller PCB is faulty.
Code: E531-8001
Description: Staple home position error
Stapler fails to move from the staple home position although the Staple Motor is driven for a specified period of time.
Remedy: 1. The wiring between the finisher controller PCB and stapler is faulty. 2. The stapler is faulty. 3. The finisher controller PCB is faulty.conds.
Code: E531-8002
Description: Staple home position error
Stapler fails to move from the staple home position although the Staple Motor is driven for a specified period of time.
Remedy: 1. The wiring between the finisher controller PCB and stapler is faulty. 2. The stapler is faulty. 3. The finisher controller PCB is faulty.conds.
Code: E532-0001
Description: STP Move Motor fails to move from HP (Inner Finisher)
At initial rotation, when the Motor rotates for specified period of time and cannot move from HP, it is detected as an error if the same symptom occurs again after the first retry.
Remedy: 1. Check if the Motor (M1) Connector is physically removed. 2. Check if the Motor failure occurs. 3. Check if the Stapler Move HP Sensor (S10) Connector is physically removed. 4. Check if the Stapler Move HP Sensor (S10) failure occurs.
Code: E532-0002
Description: STP Move Motor fails to return to HP (Inner Finisher)
At initial rotation, when the Motor rotates for specified period of time and cannot return to HP, it is detected as an error if the same symptom occurs again after the first retry.
Remedy: 1. Check if the Motor (M1) Connector is physically removed. 2. Check if the Motor failure occurs. 3. Check if the Stapler Move HP Sensor (S10) Connector is physically removed. 4. Check if the Stapler Move HP Sensor (S10) failure occurs.
Code: E532-8001
Description: Stapler shift home position error (Staple/Booklet Finisher)
The stapler does not leave the stapler shift home position when the stapler shift motor has been driven for 5 seconds.
Remedy: 1. The stapler drive home position sensor (PI110) is faulty. 2. The wiring between the finisher controller PCB and stapler shift motor is faulty. 3. The stapler shift base is faulty. 4. The stapler shift motor (M105) is faulty. 5. The finisher controller PCB is faulty.
Code: E532-8002
Description: Stapler shift home position error (Staple/Booklet Finisher)
The stapler does not return to the stapler shift home position when the stapler shift motor has been driven for 20 seconds.
Remedy: 1. The stapler drive home position sensor (PI110) is faulty. 2. The wiring between the finisher controller PCB and stapler shift motor is faulty. 3. The stapler shift base is faulty. 4. The stapler shift motor (M105) is faulty. 5. The finisher controller PCB is faulty.
Code: E535-8002
Description: Swing home position error
The stapler does not return to the swing home position when the swing motor has bee driven for 3 seconds.
Remedy: 1. The swing home position sensor (PI105) is faulty. 2. The wiring between the finisher controller PCB and swing motor is faulty. 3. The swing mechanism is faulty. 4. The swing motor (M106) is faulty. 5. The finisher controller PCB is faulty.