Causes: The pressurization of the Fixing Pressure Release Sensor (S53) was not detected for 1.5 seconds during the Fixing Motor(M2) pressurization drive.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J307) to the Fixing Pressure Release Sensor (S53/J710) - Fixing Pressure Release Sensor (S53) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the harness and connector between the DC Controller PCB and the Fixing Main Thermistor. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Causes: The pressure release of the Fixing Pressure Release Sensor (S53) was not detected for 1.5 seconds during the Fixing Motor(M2) pressure release drive.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J307) to the Fixing Pressure Release Sensor (S53/J710) - Fixing Pressure Release Sensor (S53) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the harness and connector between the DC Controller PCB and the Fixing Main Thermistor. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Unstable rotation of the Main Motor (M1)
Causes: Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J309) to the Main Motor (M1/J137) - Main Motor (M1) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Unstable rotation of the Main Motor (M1)
Causes: During motor rotation, detection is executed every 100 msec; however, the drive signal is absent 5 times in sequence.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J309) to the Main Motor (M1/J137) - Main Motor (M1) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Unstable rotation of the Fixing Motor (M2)
Causes: Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J331) to the Fixing Motor (M2/J730) - Fixing Motor (M2) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Unstable rotation of the Fixing Motor (M2)
Causes: During motor rotation, detection is executed every 100 msec; however, the drive signal is absent 5 times in sequence.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J331) to the Fixing Motor (M2/J730) - Fixing Motor (M2) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: The path between the sub hopper and the developing assembly is clogged with toner.
Causes: The Developing Assembly Toner Level Sensor (S25) detects the absence of toner, while the Developing Assembly Toner Level Sensor (S51) detects the presence of toner. * Error occurs after the delivery if a paper in passage exists.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J301) to the Developing Assembly Toner Level Sensor (S25/J25) - Harness connecting from the DC Controller PCB (UN2/J333) to the Developing Assembly Toner Level Sensor (S51/J44) - Developing Assembly Toner Level Sensor (S25) - Developing Assembly Toner Level Sensor (S51) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: The connector of Developing Assembly Toner Level Sensor (S25) is disconnected.
Causes: The Developing Assembly Toner Level Sensor (S25) connection detection signal is absent for 100 msec 10 times in sequence. * Error occurs after the delivery if a paper in passage exists.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J301) to the Developing Assembly Toner Level Sensor (S25/J25) - Developing Assembly Toner Level Sensor (S25) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.