Causes: An error in the Reader Scanner Unit position was detected when reading of a job was started.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN_BO1/J102) and the Scanner Unit HP Sensor (PS_A1/J5002) - Harness between the Reader Controller PCB (UN_BO1/J108) and the Scanner Motor (STM1/ J5015) - Scanner Unit HP Sensor (PS_A1) - Scanner Motor (STM1) - Reader Controller PCB (UN_BO1) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Code: 202-0004-04
Description: Reader Scanner Unit HP error
Causes: Home position error of the Reader Scanner Unit was detected when reading of a job was completed.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN_BO1/J102) and the Scanner Unit HP Sensor (PS_A1/J5002) - Harness between the Reader Controller PCB (UN_BO1/J108) and the Scanner Motor (STM1/ J5015) - Scanner Unit HP Sensor (PS_A1) - Scanner Motor (STM1) - Reader Controller PCB (UN_BO1) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Code: 202-0101-04
Description: DADF Scanner Unit HP error
Causes: The DADF Scanner Unit could not detect the home position when starting scanning operation.
Remedy: [Related parts] R1.00 - Harness between the DADF Driver PCB (PCB1/J408) and the Glass Movement HP Sensor (PS_ A9/J462) - Glass Movement HP Sensor (PS_A9) - Glass Movement Gear 18T - DADF Driver PCB (PCB1) [Remedy] Check/replace the related harness/cable, connector and parts.
Code: 202-0102-04
Description: DADF Scanner Unit HP error
Causes: The DADF Scanner Unit could not detect the home position when completing scanning operation.
Remedy: [Related parts] R1.00 - Harness between the DADF Driver PCB (PCB1/J408) and the Glass Movement HP Sensor (PS_ A9/J462) - Glass Movement HP Sensor (PS_A9) - Glass Movement Gear 18T - DADF Driver PCB (PCB1) [Remedy] Check/replace the related harness/cable, connector and parts.
Code: 227-0001-04
Description: Power supply error
Causes: The Reader Controller PCB did not detect 24 V when the main power was turned ON.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN_BO1/J104) and the DADF Driver PCB (PCB1/ J402) - Harness between the Reader Controller PCB (UN_BO1/J101) and the AC Driver PCB (UN30/ J118) - Harness between the AC Driver PCB (UN30/J112) and the 12V/24V Power Supply PCB (UN5/ CN52) - Reader Controller PCB (UN_BO1) - DADF Driver PCB (PCB1) - AC Driver PCB (UN30) - 12V/24V Power Supply PCB (UN5) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - When an error is detected, conduction of 24 V is stopped. At power check, check if 24 V is conducted or rated voltage is output by repeating power cycling of the machine. - Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Code: 227-0101-04
Description: Power supply error
Causes: The DADF Driver PCB did not detect 24 V when the main power was turned ON.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN_BO1/J104) and the DADF Driver PCB (PCB1/ J402) - Harness between the Reader Controller PCB (UN_BO1/J101) and the AC Driver PCB (UN30/ J118) - Harness between the AC Driver PCB (UN30/J112) and the 12V/24V Power Supply PCB (UN5/ CN52) - Reader Controller PCB (UN_BO1) - DADF Driver PCB (PCB1) - AC Driver PCB (UN30) - 12V/24V Power Supply PCB (UN5) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - When an error is detected, conduction of 24 V is stopped. At power check, check if 24 V is conducted or rated voltage is output by repeating power cycling of the machine. - Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Code: 240-0000-05
Description: Error in controller communication
Causes: The serial communication error such as parity error or overrun error is constantly detected.
Remedy: [Related parts] - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: 240-0001-05
Description: Error in controller communication
Causes: The serial communication error such as parity error or overrun error is detected while printing.
Remedy: [Related parts] - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES