Các lỗi thường gặp

Code :
  • Code: 750-0001-05
  • Description: System software error
  • Causes: Model information of the DC Controller did not match the notification from the controller.
  • Remedy: Reinstall the system software using SST or a USB memory.
  • Code: 753-0001-00
  • Description: Download Error
  • Causes: Update of the system software failed.
  • Remedy: Perform the following in the order while checking whether the error is cleared. 1. Turn OFF and then ON the main power. 2. Reinstall the system software using SST or a USB flash drive. 3. Replace the FLASH PCB, and reinstall the system software. 4. Collect debug log and contact the sales company.
  • Code: 753-0001-05
  • Description: Download error
  • Causes: System Software Update Error Error occurs when updating system software of uninstalled options
  • Remedy: [Remedy] 1. Turn OFF and then ON the main power. 2. Reinstall the system software using SST or a USB memory. 3. Replace the FLASH PCB, and reinstall the system software. 4. Collect debug log and contact the sales.
  • Code: 760-0001-00
  • Description: Main Controller PCB internal error
  • Causes: An error was detected in the Main Controller PCB.
  • Remedy: Check/replace the Main Controller PCB
  • Code: 800-0000-05
  • Description: Power condition unmatched error between Main Controller PCB and DC Controller PCB
  • Causes: The power of DC controller PCB still keep ON even if it reaches 90 sec after detecting the power OFF by the main controller PCB.
  • Remedy: [Remedy] 1. Wait till the power is turned off. 2. Turn the main power switch ON.
  • Code: 804-0000-00
  • Description: Power Supply Fan error
  • Causes: It was detected that the Supply Fan was locked.
  • Remedy: [Related parts] R1.00 - Harness between the AC Driver PCB (UN30/J117) and the Power Supply Cooling Fan (FM5/ J712) - Power Supply Cooling Fan (FM5) - AC Driver PCB (UN30) [Remedy] Check/replace the related harness/cable, connector and parts.
  • Code: 804-0000-05
  • Description: Failure of the Power Supply Cooling Fan (FM5)
  • Causes: When lock signal is detected for 5 sec while the Power Supply Cooling Fan (FM5) is stopped. * The same condition is detected after the error retry is performed.
  • Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J117) to the Power Supply Cooling Fan (FM5/J712) - Power Supply Cooling Fan (FM5) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the Power Supply Cooling Fan.
  • Code: 804-0001-05
  • Description: Unstable rotation of the Power Supply Cooling Fan (FM5)
  • Causes: The fan stop signal is detected for 5 minutes or more and the retry operation fails 4 times continuously after generating the ON signal of the Power Supply Cooling Fan (FM5).
  • Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J117) to the Power Supply Cooling Fan (FM5/J712) - Power Supply Cooling Fan (FM5) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the Power Supply Cooling Fan.