Description: Device abnormal completion
An abnormal signal from the Main Controller PCB to the Reader is detected.
Remedy: 1. Turn OFF and then ON the main power.
2. Check the connection of the Main Controller PCB (including the flat cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB (PCB2).
Code: E315-0550
Description: Device timeout
An image synchronous signal from the Main Controller PCB to the Reader is not received within 30 seconds.
Remedy: 1. Turn OFF and then ON the main power.
2. Check the connection of the Main Controller PCB (including the flat cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB (PCB2).
Code: E315-0551
Description: Device abnormal completion
An abnormal signal from the Main Controller PCB to the Reader is detected.
Remedy: 1. Turn OFF and then ON the main power.
2. Check the connection of the Main Controller PCB (including the flat cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB (PCB2).
Code: E350
Description: System error
Remedy: Contact the service company office
Code: E351-0000
Description: Main Controller PCB communication error
Remedy: 1. Turn OFF and then ON the main power
2. Disconnect and then connect the connector of the Main Controller PCB.
3. Replace the Main Controller PCB (PCB2).
Code: E354
Description: System error
Remedy: Contact the service company office
Code: E355
Description: System error
Remedy: Contact the service company office
Code: E500-0000
Description: Communication error
As for the communication with the Finisher and the Host Machine, the retry of the communication was over the specified number of times.
Remedy: 1. Check the installation of the Host Machine and the Finisher.
2. Check the connector connection between the DC Controller PCB (PCB1) and the Finisher Controller PCB (PCB1).
3. Replace the Finisher Controller PCB (PCB1).
4. Replace the DC Controller PCB (PCB1).