Code: E713-0020

Description: Finisher IPC communication error (recovery error)
Communication between the host machine and the Finisher was lost.
Remedy: 1. Check the cable connection of the Finisher. DC Controller side: J462, Finisher Lattice side: J9043 2. Replace the Finisher Controller PCB.

Code: E713-0040

Description: Finisher IPC communication error (serial error)
Communication between the host machine and the Finisher was lost.
Remedy: 1. Check the cable connection of the Finisher. DC Controller side: J462, Finisher Lattice side: J9043 2. Replace the Finisher Controller PCB.

Code: E717-0001

Description: Communication error with the NE Controller
Error when the NE Controller is started. The NE Controller which was connected before turning OFF the power is not connected at power-on.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.

Code: E717-0002

Description: Communication error with the NE Controller
IPC error at NE Controller operation. Open circuit of IPC, unable to recover the IPC communication.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.

Code: E719-0001

Description: Error in coin manager
Error when the coin manager is started. The coin manager which was connected before turning OFF the power is not connected at power-on.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.

Code: E719-0002

Description: Error in coin manager
IPC error at coin manager operation. Open circuit of IPC, unable to recover the IPC communication. When open circuit of the pickup/delivery signal cable is detected. Invalid connection is detected.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.

Code: E719-0003

Description: Error in coin manager
Communication error with the coin manager occurs during unit price acquisition at startup.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.

Code: E719-0011

Description: Error when the Card Reader is started
The Card Reader which was connected before turning OFF the power is not connected at power-on.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie