Description: Power supply (24V) error
24V port is OFF when the power of DADF is turned ON.
Remedy: 1. Connection error between the DADF Driver PCB (PCB1) and the Reader Controller PCB (PCB1). 2. Connector disconnection/open circuit of the Reader Power Supply. 3. Failure of power supply.
Description: Power supply (24V) error
24V port is OFF when a job is started in the DADF.
Remedy: 1. Connection error between the DADF Driver PCB (PCB1) and the Reader Controller PCB (PCB1). 2. Connector disconnection/open circuit of the Reader Power Supply. 3. Failure of power supply.
Description: Power supply (24V) error
24V port is OFF when a job is ended in the DADF.
Remedy: 1. Connection error between the DADF Driver PCB (PCB1) and the Reader Controller PCB (PCB1). 2. Connector disconnection/open circuit of the Reader Power Supply. 3. Failure of power supply.
Description: Communication error between Main Controller and DC Controller
Communication error occurs between the CPU of the Main Controller PCB and the DC Controller PCB (PCB1).
Remedy: 1. Check the connection of the Main Controller PCB and the DC Controller PCB (PCB1). Main Controller side: J712, DC Controller side: J442 2. Replace the DC Controller PCB (PCB1). 3. Replace the Main Controller PCB.
Description: 3 minutes passed with pickup request waiting status
It was detected that 3 minutes passed with pickup request waiting status.
Remedy: 1. Check the connection of the Connector. 2. Check the connection of the Sub PCB in the Main Controller PCB 1 Box. 3. Check the connections of the DC Controller PCB and the Main Controller PCB 1. Replace the PCB(s) if necessary.
Description: 3 minutes passed with image output request waiting status
It was detected that 3 minutes passed with image output request waiting status.
Remedy: 1. Check the connection of the Connector. 2. Check the connection of the Sub PCB in the Main Controller PCB 1 Box. 3. Check the connections of the DC Controller PCB and the Main Controller PCB 1. Replace the PCB(s) if necessary.
Description: Software sequence error after the jam
A software sequence error (engine bug) was detected after the jam.?
Remedy: 1. Check the connection of the Connector. 2. Check the connection of the Sub PCB in the Main Controller PCB 1 Box. 3. Check the connections of the DC Controller PCB and the Main Controller PCB 1. Replace the PCB(s) if necessary.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.