Các lỗi thường gặp

Code :
  • Code: E804-0001
  • Description: Fixing Power Supply Cooling Fan error
    The Fan stop signal is detected for 1.5 seconds or longer and retry is failed 4 times in a row although the Fixing Power Supply Cooling Fan (FM7) is turned ON.
  • Remedy: 1. Check the connection of the Connector. 2. Replace the Fixing Power Supply Cooling Fan (FM7).
  • Code: E806-0000
  • Description: Making Image Exhaust Fan error
    The Fan stop signal is detected for 5 seconds or longer and retry is failed 4 times in a row although the Making Image Exhaust Fan (FM3) is turned ON.
  • Remedy: 1. Check the connection of the Connector. 2. Replace the Making Image Exhaust Fan (FM3).
  • Code: E808-0001
  • Description: Fixing Power Supply error
    Detected 145V (100V/120V model)/290V (230V model) or higher inlet voltage at power-on.
  • Remedy: 1. Check the outlet voltage. -> Connect to the correct outlet. 2. Check the connection between the Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10). 3. Replace the Fixing Power Supply PCB (PCB10). 4. Replace the Main Driver PCB (PCB2).
  • Code: E808-0002
  • Description: Fixing Power Supply error
    Detected 75 V (100V/120V model)/150 V (230V model) or higher inlet voltage at power-on.
  • Remedy: 1. Check the outlet voltage. -> Connect to the correct outlet. 2. Check the connection between the Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10). 3. Replace the Fixing Power Supply PCB (PCB10). 4. Replace the Main Driver PCB (PCB2).
  • Code: E808-0003
  • Description: Fixing Power Supply error
    Inlet current is 1A or lower for 1 second or longer although the maximum voltage is output.
  • Remedy: 1. Check the clogging of the Fixing Power Supply Cooling Fan (FM7). 2. Check the clogging of the Louver on right side of the host machine (Multi-purpose Tray side). 3. Check the connection of the Fixing Power Supply PCB (PCB10) Output Connector. 4. Replace the Fixing Power Supply PCB (PCB10).
  • Code: E808-0004
  • Description: Fixing Power Supply error
    Detected OFF with 12V of the Main Driver PCB (PCB2) output.
  • Remedy: Replace the Main Driver PCB (PCB2).
  • Code: E808-0005
  • Description: 12V OFF detection when relay is turned ON
    Detected OFF with 12V of the Fixing Power Supply output after IH relay is turned ON.
  • Remedy: 1. Check the conduction of the Fixing Thermal Switch 1/2 (TP1/2). 2. Check the drawer between the Fixing Assembly and the host machine. 3. Check the connection between the Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10). 4. Replace the Fixing Power Supply Unit. 5. Replace the Main Driver PCB (PCB2).
  • Code: E808-0006
  • Description: ASIC error
  • Remedy: Replace the DC Controller PCB (PCB1).