Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR Advance 6065 — Trang 40/40

Code: E880-0001

Description: Controller Fan error
Error in the Main Controller Cooling Fan (FM4) is detected.
Remedy: Connector disconnection, failure of Fan.

Code: E880-0005

Description: Controller Fan error
Connector disconnection, failure of Fan.
Remedy: Error in the HDD Cooling Fan (FM) is detected.

Code: E905-0001

Description: POD Deck Air Assist Fan error
[POD Deck Lite] When the Air Assist Swing Motor fails to return to the HP although a specified period of time has passed
Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J04, J05 BoxDriver J51, J52, J57 2. Replace the Swing Motor (M3) and the Air Assist Fan (FM1, FM2, FM3). 3. Replace the Deck Lite Controller PCB. 4. Replace the BoxDriver PCB.

Code: E905-0002

Description: POD Deck Air Assist Fan error
[POD Deck Lite] When the Pickup Motor Cooling Fan is not locked
Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J30 2. Replace the Motor Cooling Fan (FM4). 3. Replace the Deck Lite Controller PCB.

Code: E905-0003

Description: POD Deck Air Assist Fan error
[POD Deck Lite] When the Pickup Motor Cooling Fan is not unlocked
Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J30 2. Replace the Motor Cooling Fan (FM4). 3. Replace the Deck Lite Controller PCB.

Code: E906-0001

Description: POD Deck Air Heater error[
POD Deck Lite] Air Heater high temperature error When 120 deg C or higher temperature is detected for 1 second consecutively
Remedy: 1. Check connector disconnection/improper connection. - > Disconnect and then connect the connector. Target connector: Deck Lite Controller J03, J05 BoxDriver J52, J54, J58, J59 2. Replace the Air Heater. 3. Replace the Deck Lite Controller PCB

Code: E906-0002

Description: POD Deck Air Heater errorr high.
[POD Deck Lite] Air Heater low temperature error When the heater does not become Ready although a specified period of time has passed.
Remedy: 1. Check connector disconnection/improper connection. - > Disconnect and then connect the connector. Target connector: Deck Lite Controller J03, J05 BoxDriver J52, J54, J58, J59 2. Replace the Air Heater. 3. Replace the Deck Lite Controller PCB.

Code: E996-xxxx

Description: Timeout error
The DC Controller is not stopped. The Detailed Code varies according to the state transition of the software.
Remedy: Turn OFF and then ON the main power.