Description: Finisher IPC communication error (recovery error)
Communication between the host machine and the Finisher was lost.
Remedy: 1. Check the cable connection of the Finisher. DC Controller side: J462, Finisher Lattice side: J9043 2. Replace the Finisher Controller PCB.
Code: E713-0040
Description: Finisher IPC communication error (serial error)
Communication between the host machine and the Finisher was lost.
Remedy: 1. Check the cable connection of the Finisher. DC Controller side: J462, Finisher Lattice side: J9043 2. Replace the Finisher Controller PCB.
Code: E717-0001
Description: Communication error with the NE Controller
Error when the NE Controller is started. The NE Controller which was connected before turning OFF the power is not connected at power-on.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
Code: E717-0002
Description: Communication error with the NE Controller
IPC error at NE Controller operation. Open circuit of IPC, unable to recover the IPC communication.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
Code: E719-0001
Description: Error in coin manager
Error when the coin manager is started. The coin manager which was connected before turning OFF the power is not connected at power-on.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
Code: E719-0002
Description: Error in coin manager
IPC error at coin manager operation. Open circuit of IPC, unable to recover the IPC communication. When open circuit of the pickup/delivery signal cable is detected. Invalid connection is detected.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
Code: E719-0003
Description: Error in coin manager
Communication error with the coin manager occurs during unit price acquisition at startup.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
Code: E719-0011
Description: Error when the Card Reader is started
The Card Reader which was connected before turning OFF the power is not connected at power-on.
Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.