Description: Serial communication error
Failure of reception from the video signal control ASIC. Data reception was failed 5 times in a row when reading data from the video signal control ASIC (at FG lock detection, BD lock detection).
Remedy: Replace the DC Controller PCB (PCB1).
Code: E202-0001
Description: Scanner HP error
An error occurs during the Scanner Unit (Paper Front) HP detection operation (outward).
Remedy: 1. Connector disconnection/open circuit of the Scanner HP Sensor (SR2). 2. Failure of the Scanner HP Sensor (SR2). 3. Failure of the Scanner Motor (M1). 4. Failure of the Reader Controller PCB (PCB1).
Code: E202-0002
Description: Scanner HP error
An error occurs during the Scanner Unit (Paper Front) HP detection operation (homeward).
Remedy: 1. Connector disconnection/open circuit of the Scanner HP Sensor (SR2). 2. Failure of the Scanner HP Sensor (SR2). 3. Failure of the Scanner Motor (M1). 4. Failure of the Reader Controller PCB (PCB1).
Code: E202-0101
Description: Glass HP error
An error occurs during the Glass HP detection operation (outward).
Remedy: 1. Connector disconnection/open circuit of the Glass Shift HP Sensor (SR11). 2. Failure of the Glass Shift HP Sensor (SR11). 3. Failure of the Glass Shift Motor (M9). 4. Failure of the DADF Driver PCB (PCB1).
Code: E202-0102
Description: Glass HP error
An error occurs during the Glass HP detection operation (homeward).
Remedy: 1. Connector disconnection/open circuit of the Glass Shift HP Sensor (SR11). 2. Failure of the Glass Shift HP Sensor (SR11). 3. Failure of the Glass Shift Motor (M9). 4. Failure of the DADF Driver PCB (PCB1).
Code: E227-0001
Description: Power supply (24V) error
24V port is OFF when the power is turned ON.B
Remedy: 1. Connector disconnection/open circuit of the Reader Power Supply. 2. Failure of power supply.
Code: E227-0002
Description: Power supply (24V) error
24V port is OFF when a job is started.
Remedy: 1. Connector disconnection/open circuit of the Reader Power Supply. 2. Failure of power supply.
Code: E227-0003
Description: Power supply (24V) error
24V port is OFF when a job is ended.
Remedy: 1. Connector disconnection/open circuit of the Reader Power Supply. 2. Failure of power supply