Description: Fixing Assembly temperature decrease error
The Fixing Main Thermistor (THM1) detects 70 degC or lower for 2 seconds or longer although the temperature reached above 100 degC after starting the Fixing Roller temperature control.
Remedy: 1. Check the connection of the Fixing Main Thermistor (THM1). -> Replace the Fixing Main Thermistor Unit. 2. Check the installation of the Fixing Main Thermistor. -> Replace the Fixing Upper Unit. 3. Replace the Fixing Power Supply PCB (PCB10). 4. Replace the Main Driver PCB (PCB2). 5. Replace the DC Controller PCB (PCB1). 6. Replace the Relay PCB (PCB5).
Description: Fixing Power Supply error
Detect that the Fixing Main Thermistor Unit is not connected.
Remedy: 1. Check the harness of the Fixing Main Thermistor (THM1) in the Fixing Assembly. 2. Check the connection of the harness of the Fixing Assembly on the host machine side. 3. Replace the Main Driver PCB (PCB2).
Description: Fixing Cleaning Web absent error
After noticing the Fixing Cleaning Web absent, the web was pulled out 2000 times.
Remedy: 1. Replace the Fixing Cleaning Web. 2. Replace the Fixing Cleaning Web Level Sensor (PS45). 3. Replace the DC Controller PCB (PCB1). After executing the measures, clear the Fixing Cleaning Web counter (COPIER > COUNTER > MISC > FIXWEB).
Description: Error in Fixing Cleaning Web Drive Solenoid connection
Connection of the Fixing Cleaning Web Drive Solenoid (SL9) is not detected when the power is turned ON.
Remedy: 1. Check the connection of the Connector. 2. Replace the Fixing Cleaning Web Drive Solenoid (SL9).