Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR Advance 6275i — Trang 11/40

Code: E227-0004

Description: Power supply (24V) error
24V port is OFF when loading.
Remedy: 1. Connector disconnection/open circuit of the Reader Power Supply. 2. Failure of power supply.

Code: E227-0101

Description: Power supply (24V) error
24V port is OFF when the power of DADF is turned ON.
Remedy: 1. Connection error between the DADF Driver PCB (PCB1) and the Reader Controller PCB (PCB1). 2. Connector disconnection/open circuit of the Reader Power Supply. 3. Failure of power supply.

Code: E227-0102

Description: Power supply (24V) error
24V port is OFF when a job is started in the DADF.
Remedy: 1. Connection error between the DADF Driver PCB (PCB1) and the Reader Controller PCB (PCB1). 2. Connector disconnection/open circuit of the Reader Power Supply. 3. Failure of power supply.

Code: E227-0103

Description: Power supply (24V) error
24V port is OFF when a job is ended in the DADF.
Remedy: 1. Connection error between the DADF Driver PCB (PCB1) and the Reader Controller PCB (PCB1). 2. Connector disconnection/open circuit of the Reader Power Supply. 3. Failure of power supply.

Code: E240-0000

Description: Communication error between Main Controller and DC Controller
Communication error occurs between the CPU of the Main Controller PCB and the DC Controller PCB (PCB1).
Remedy: 1. Check the connection of the Main Controller PCB and the DC Controller PCB (PCB1). Main Controller side: J712, DC Controller side: J442 2. Replace the DC Controller PCB (PCB1). 3. Replace the Main Controller PCB.

Code: E240-0001

Description: 3 minutes passed with pickup request waiting status
It was detected that 3 minutes passed with pickup request waiting status.
Remedy: 1. Check the connection of the Connector. 2. Check the connection of the Sub PCB in the Main Controller PCB 1 Box. 3. Check the connections of the DC Controller PCB and the Main Controller PCB 1. Replace the PCB(s) if necessary.

Code: E240-0002

Description: 3 minutes passed with image output request waiting status
It was detected that 3 minutes passed with image output request waiting status.
Remedy: 1. Check the connection of the Connector. 2. Check the connection of the Sub PCB in the Main Controller PCB 1 Box. 3. Check the connections of the DC Controller PCB and the Main Controller PCB 1. Replace the PCB(s) if necessary.

Code: E240-0003

Description: Software sequence error after the jam
A software sequence error (engine bug) was detected after the jam.?
Remedy: 1. Check the connection of the Connector. 2. Check the connection of the Sub PCB in the Main Controller PCB 1 Box. 3. Check the connections of the DC Controller PCB and the Main Controller PCB 1. Replace the PCB(s) if necessary.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie