Causes: [POD Deck Lite] When the Pickup Motor Cooling Fan is not unlocked
Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J30 2. Replace the Motor Cooling Fan (FM4). 3. Replace the Deck Lite Controller PCB.
Code: 906-0001-05
Description: POD Deck Air Heater error
Causes: [POD Deck Lite] Air Heater high temperature error When 120 deg C or higher temperature is detected for 1 second consecutively
Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J03, J05 BoxDriver J52, J54, J58, J59 2. Replace the Air Heater. 3. Replace the Deck Lite Controller PCB.
Code: 906-0002-05
Description: POD Deck Air Heater error
Causes: [POD Deck Lite] Air Heater low temperature error When the heater does not become Ready although a specified period of time has passed
Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J03, J05 BoxDriver J52, J54, J58, J59 2. Replace the Air Heater. 3. Replace the Deck Lite Controller PCB.
Code: 996-0071-04
Description: Error for collecting sequence jam log (ADF)
Causes: Error for collecting jam log (ADF)
Remedy: [Remedy] Collect debug log and contact to the sales company. [Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> JM-ERR-R" to "1", it is handled as an error instead of a jam from the first occurrence.
Code: 996-0CA1-05
Description: Error for collecting sequence jam log (Printer)
Causes: Error for collecting jam log (Printer)
Remedy: Collect debug log and contact to the sales company. [Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> JM-ERR-D" to "1", it is handled as an error instead of a jam from the first occurrence.
Code: 996-0CA2-05
Description: Error for collecting sequence jam log (Printer)
Causes: Error for collecting jam log (Printer)
Remedy: Collect debug log and contact to the sales company. [Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> JM-ERR-D" to "1", it is handled as an error instead of a jam from the first occurrence.
Code: 996-0CA3-05
Description: Error for collecting sequence jam log (Printer)
Causes: Error for collecting jam log (Printer)
Remedy: Collect debug log and contact to the sales company. [Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> JM-ERR-D" to "1", it is handled as an error instead of a jam from the first occurrence.
Code: 996-0CA4-05
Description: Error for collecting sequence jam log (Printer)
Causes: Error for collecting jam log (Printer)
Remedy: Collect debug log and contact to the sales company. [Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> JM-ERR-D" to "1", it is handled as an error instead of a jam from the first occurrence.