Mã lỗi Canon iR Advance 8095 Pro — Trang 46/54

Code: E719-0031

Description: Communication error when the Card Reader (serial) is started. Unable to start communication with the Card Reader at startup.
Remedy: 1. Check the cable connection of the Card Reader (connector connection error, open circuit), and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR. 2. After removing the Card Reader, execute the following service mode, and then reinstall the Card Reader. COPIER>FUNCTION>CLEAR>CARD COPIER>FUNCTION>CLEAR>ERR

Code: E719-0032

Description: Communication error after the Card Reader (serial) is started. Although communication with the Card Reader was possible at startup, it became unavailable in the middle of it.
Remedy: Check the cable connection of the Card Reader (connector connection error, open circuit), and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.

Code: E720-0001

Description: Different model error. Not proper Finisher is connected.
Remedy: Check the configuration of options.

Code: E720-0002

Description: Different model error. Not proper Option Deck is connected.
Remedy: Check the configuration of options.

Code: E730-1001

Description: PDL software error. Initialization error.
Remedy: 1. PDL reset processing. 2. Turn OFF and then ON the power.

Code: E730-100A

Description: PDL software error. Systematic fatal error, such as initialization failure, occurs.
Remedy: 1. PDL reset processing. 2. Turn OFF and then ON the power.

Code: E730-9004

Description: Third party PDL communication error. Communication error with the print server.
Remedy: 1. Turn OFF and then ON the power. 2. Check the cable connection. 3. Replace the Open I/F PCB, F Link PCB (Main/Sub). 4. Replace the Main Controller PCB.

Code: E730-9005

Description: Third party PDL communication error. Error in video cable connection with the print server.
Remedy: 1. Turn OFF and then ON the power. 2. Check the cable connection. 3. Replace the Open I/F PCB, F Link PCB (Main/Sub). 4. Replace the Main Controller PCB.