Description: Fixing Assembly temperature decrease error. The Fixing Main Thermistor (THM1) detects 70 degC or lower for 2 seconds or longer although the temperature reached above 100 degC after starting the Fixing Roller temperature control.
Remedy: 1. Check the connection of the Fixing Main Thermistor (THM1). -> Replace the Fixing Main Thermistor Unit. 2. Check the installation of the Fixing Main Thermistor. -> Replace the Fixing Assembly. 3. Replace the Fixing Power Supply PCB (PCB10). 4. Replace the Main Driver PCB (PCB2). 5. Replace the DC Controller PCB (PCB1). 6. Replace the Relay PCB (PCB5).
Description: Fixing Power Supply error. Detect that the Fixing Main Thermistor (THM1) is not connected.
Remedy: 1. Check the harness of the Fixing Main Thermistor (THM1) in the Fixing Assembly. 2. Check the connection of the harness of the Fixing Assembly on the host machine side. 3. Replace the Main Driver PCB (PCB2).
Description: Fixing Cleaning Web absent error. After noticing the Fixing Cleaning Web absent, the web was pulled out 2000 times.
Remedy: 1. Replace the Fixing Cleaning Web. 2. Replace the Fixing Cleaning Web Level Sensor (PS45). 3. Replace the DC Controller PCB (PCB1). After executing the measures, clear the Fixing Cleaning Web counter (COPIER > COUNTER > MISC > FIXWEB).
Description: Error in Fixing Cleaning Web Drive Solenoid connection. Connection of the Fixing Cleaning Web Drive Solenoid (SL9) is not detected when the power is turned ON.
Remedy: 1. Check the connection of the Connector. 2. Replace the Fixing Cleaning Web Drive Solenoid (SL9).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.