Các lỗi thường gặp

Code :
  • Code: E530-8001
  • Description: Front aligning plate home position error
    The aligning plate does not leave the aligningplate front home position sensor when thealignment plate front motor has been driven for 4 seconds.
  • Remedy: 1. The front aligning plate home position sensor (PI106) is faulty. 2. The wiring between the finisher controller PCB and front aligning plate motor is faulty. 3. The front aligning plate is faulty. 4. The front aligning plate motor (M103) is faulty. 5. The finisher controller PCB is faulty.
  • Code: E530-8002
  • Description: Front aligning plate home position error
    The aligning plate does not return to aligning plate front home position sensor when the alignment plate front motor has been driven for 4 seconds.
  • Remedy: 1. The front aligning plate home position sensor (PI106) is faulty. 2. The wiring between the finisher controller PCB and front aligning plate motor is faulty. 3. The front aligning plate is faulty. 4. The front aligning plate motor (M103) is faulty. 5. The finisher controller PCB is faulty.
  • Code: E531-8001
  • Description: Stapler Motor fails to move from HP
    At initial rotation, when the Motor rotates for specified period of time and cannot move from HP, it is detected as an error if the same symptom occurs again after the first retry.
  • Remedy: 1. Check if the Motor (M10) Connector is physically removed. 2. Replace the Motor. 3. Check if the Stapler HP Sensor (S18) Connector is physically removed. 4. Replace the Stapler HP Sensor (S18).
  • Code: E531-8002
  • Description: Stapler Motor fails to return to HP
    At initial rotation, when the Motor rotates for specified period of time and cannot return to HP, it is detected as an error if the same symptom occurs again after the first retry.
  • Remedy: 1. Check if the Motor (M10) Connector is physically removed. 2. Replace the Motor. 3. Check if the Stapler HP Sensor (S18) Connector is physically removed. 4. Replace the Stapler HP Sensor (S18).
  • Code: E532-0001
  • Description: STP Move Motor fails to move from HP
    At initial rotation, when the Motor rotates for specified period of time and cannot move from HP, it is detected as an error if the same symptom occurs again after the first retry.
  • Remedy: 1. Check if the Motor (M1) Connector is physically removed. 2. Replace the Motor. 3. Check if the Stapler Move HP Sensor (S10) Connector is physically removed. 4. Replace the Stapler Move HP Sensor (S10).
  • Code: E532-0002
  • Description: STP Move Motor fails to return to HP
    At initial rotation, when the Motor rotates for specified period of time and cannot return to HP, it is detected as an error if the same symptom occurs again after the first retry.
  • Remedy: 1. Check if the Motor (M1) Connector is physically removed. 2. Replace the Motor. 3. Check if the Stapler Move HP Sensor (S10) Connector is physically removed. 4. Replace the Stapler Move HP Sensor (S10).
  • Code: E532-8001
  • Description: Stapler shift home position error
    The stapler does not leave the stapler shifthome position when the stapler shift motor hasbeen driven for 5 seconds.
  • Remedy: 1. The stapler drive home position sensor (PI110) is faulty. 2. The wiring between the finisher controller PCB and stapler shift motor is faulty. 3. The stapler shift base is faulty. 4. The stapler shift motor (M105) is faulty. 5. The finisher controller PCB is faulty.
  • Code: E532-8002
  • Description: Stapler shift home position error
    The stapler does not return to the stapler shift home position when the stapler shift motor has been driven for 20 seconds.
  • Remedy: 1. The stapler drive home position sensor (PI110) is faulty. 2. The wiring between the finisher controller PCB and stapler shift motor is faulty. 3. The stapler shift base is faulty. 4. The stapler shift motor (M105) is faulty. 5. The finisher controller PCB is faulty.