Description: Tray 2 shift area error
The upper limit area is reached before the tray 2 paper surface sensor 1 detects the paper surface during paper surface detection operation. A discontinuous area is detected during tray operation. During evacuation operation, arrival at the area beyond the tray 2 paper surface sensor 2 is detected before this sensor detects paper surface.
Remedy: 1. The tray 2 shift area sensor PCB is faulty. 2. The wiring between the finisher controller PCB and tray 2 shift motor is faulty. 3. The tray up/down mechanism is faulty. 4. The tray 2 shift motor (M105) is faulty. 5. The finisher controller PCB is faulty.
Remedy: 1. The tray 2 shift area sensor PCB is faulty. 2. The wiring between the finisher controller PCB and tray 2 shift motor is faulty. 3. The tray up/down mechanism is faulty. 4. The tray 2 shift motor (M105) is faulty. 5. The finisher controller PCB is faulty.
Description: The tray 2 shift motor clock error
The FG input cannot be detected when the tray 2 shift motor has been driven for 0.2 second.
Remedy: 1. The Tray 2 shift area sensor PCB is faulty. 2. The wiring between the finisher controller PCB and tray 2 shift motor is faulty. 3. The tray up/down mechanism is faulty. 4. The Tray 2 shift motor (M105) is faulty. 5. The finisher controller PCB is faulty.
Description: The tray 2 shift motor speed error
The lock detection signal turns OFF 150 ms after the lock detection signal turned ON.
Remedy: 1. The tray 2 shift area sensor PCB is faulty. 2. The wiring between the finisher controller PCB and tray 2 shift motor is faulty. 3. The tray up/down mechanism is faulty. 4. The tray 2 shift motor (M105) is faulty. 5. The finisher controller PCB is faulty.
Description: The tray 2 shift motor acceleration error
The lock detection signal does not turn ON when the tray 2 shift motor has been driven for 1 second.
Remedy: 1. The tray 2 shift area sensor PCB is faulty. 2. The wiring between the finisher controller PCB and tray 2 shift motor is faulty. 3. The tray up/down mechanism is faulty. 4. The tray 2 shift motor (M105) is faulty. 5. The finisher controller PCB is faulty.
Description: The tray 2 shift motor error
The lock detection signal does not turn OFF when the tray 2 shift motor is at a stop.
Remedy: 1. The tray 2 shift area sensor PCB is faulty. 2. The wiring between the finisher controller PCB and tray 2 shift motor is faulty. 3. The tray up/down mechanism is faulty. 4. The tray 2 shift motor (M105) is faulty. 5. The finisher controller PCB is faulty.
Description: Front Fan lock error
While the front fan is rotating, this machine stops the front fan after detecting the lock signal. Then this machine retries to rotate the front fan, but lock signal is detected again, this machine displays the error.
Remedy: 1. Check the Fan (M8). 2. Replace the finisher controller PCB.
Description: Rear Fan lock error
While the rear fan is rotating, this machine stops the front fan after detecting the lock signal. Then this machine retries to rotate the rear fan, but lock signal is detected again, this machine displays the error.
Remedy: 1. Check the Fan (M9). 2. Replace the finisher controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.