Các lỗi thường gặp

Code :
  • Code: E040-0002
  • Description: Cassette 1 Lifter error
    Unable to detect the lift-up completion position within 4.5 sec after lift-up was started
  • Remedy: Error in Lift Motor or Lifter Sensor 1. While Cassette 1 is removed, turn ON the power and then insert Cassette 1. When there is operation sound of the motor 1-1. Check the harness/connector between the DC Controller (UN09/J13) and the Cassette 1 Lifter Sensor (PS12) 2-1. Check if the Cassette 1 Lifter Sensor (PS12) is installed. 3-1. Extend the Sensor Flag of the Cassette 1 Lifter Sensor (PS12) by approx. 1.5 mm with Plastic Film, etc. 4-1. Check the condition of the gear at the host machine side (to see if there is missing or swing with the gear) 5-1. Replace the Cassette 1 Lifter Sensor (PS12) 6-1. Replace the DC Controller PCB (UN09) When there is no operation sound of the motor 1-2. Check the harness/connector between the DC Controller (UN09/J13) and the Cassette 1 Lifter Motor (M14) 2-2. Check conduction of the fuse (FU2) of the DC Controller (UN09) 3-2. Check the condition of the gear at the host machine side (to see if there is something missing or swing with the gear) 4-2. Check the Cassette 1 Lifter Motor (M14) 5-2. Replace the DC Controller (UN09)
  • Code: E065-0000
  • Description: Error in detection of abnormal Y charging AC current value
    During the paper interval simple discharge current control, a current value that is higher than the target of 500[uA] is detected
  • Remedy: Error in output of charging high voltage, Drum Unit error or environment control error 1. COPIER > DISPLAY > ANALOG; check if the TEMP value and the HUM value are matched with the environment temperature. When the values are dramatically mismatched (Lager than 15degrees Celsius) 2-1. Check the harness and connector between the DC Controller (UN09/ J206) and the Environment Sensor (UN45) 3-1. Replace the Environment Sensor (UN45) 4-1. Replace the DC Controller (UN09) When the values are matched 2-2. Check the state of the charging high voltage contact point 3-2. Replace the Drum Unit (Y) 4-2. Check the harness and connector between the DC Controller PCB (UN09/ J21) and the Primary Charging High Voltage PCB (UN06/ J441, J442) 5-2. Replace the Primary Charging High Voltage PCB (UN06) 6-2. Replace the DC Controller PCB (UN09)
  • Code: E065-0000
  • Description: Error in detection of abnormal Y charging AC current value
    During the paper interval simple discharge current control, a current value that is higher than the target of 500[uA] is detected
  • Remedy: Error in output of charging high voltage, Drum Unit error or environment control error 1. COPIER > DISPLAY > ANALOG; check if the TEMP value and the HUM value are matched with the environment temperature. When the values are dramatically mismatched (Lager than 15degrees Celsius) 2-1. Check the harness and connector between the DC Controller (UN09/ J206) and the Environment Sensor (UN45) 3-1. Replace the Environment Sensor (UN45) 4-1. Replace the DC Controller (UN09) When the values are matched 2-2. Check the state of the charging high voltage contact point 3-2. Replace the Drum Unit (Y) 4-2. Check the harness and connector between the DC Controller PCB (UN09/ J21) and the Primary Charging High Voltage PCB (UN06/ J441, J442) 5-2. Replace the Primary Charging High Voltage PCB (UN06) 6-2. Replace the DC Controller PCB (UN09)
  • Code: E065-0001
  • Description: Error in detection of abnormal M charging AC current value
    During the paper interval simple discharge current control, a current value that is higher than the target of 500[uA] is detected
  • Remedy: Error in output of charging high voltage, Drum Unit error or environment control error 1. COPIER > DISPLAY > ANALOG; check if the TEMP value and the HUM value are matched with the environment temperature. When the values are dramatically mismatched (Lager than 15degrees Celsius) 2-1. Check the harness and connector between the DC Controller (UN09/ J206) and the Environment Sensor (UN45) 3-1. Replace the Environment Sensor (UN45) 4-1. Replace the DC Controller (UN9) When the values are matched 2-2. Check the state of the charging high voltage contact point 3-2. Replace the Drum Unit (M) 4-2. Check the harness and connector between the DC Controller PCB (UN09/ J21) and the Primary Charging High Voltage PCB (UN06/ J441, J442) 5-2. Replace the Primary Charging High Voltage PCB (UN06) 6-2. Replace the DC Controller PCB (UN09)
  • Code: E065-0001
  • Description: Error in detection of abnormal M charging AC current value
    During the paper interval simple discharge current control, a current value that is higher than the target of 500[uA] is detected
  • Remedy: Error in output of charging high voltage, Drum Unit error or environment control error 1. COPIER > DISPLAY > ANALOG; check if the TEMP value and the HUM value are matched with the environment temperature. When the values are dramatically mismatched (Lager than 15degrees Celsius) 2-1. Check the harness and connector between the DC Controller (UN09/ J206) and the Environment Sensor (UN45) 3-1. Replace the Environment Sensor (UN45) 4-1. Replace the DC Controller (UN9) When the values are matched 2-2. Check the state of the charging high voltage contact point 3-2. Replace the Drum Unit (M) 4-2. Check the harness and connector between the DC Controller PCB (UN09/ J21) and the Primary Charging High Voltage PCB (UN06/ J441, J442) 5-2. Replace the Primary Charging High Voltage PCB (UN06) 6-2. Replace the DC Controller PCB (UN09)
  • Code: E065-0002
  • Description: Error in detection of abnormal C charging AC current value
    During the paper interval simple discharge current control, a current value that is higher than the target of 500[uA] is detected
  • Remedy: Error in output of charging high voltage, Drum Unit error or environment control error 1. COPIER > DISPLAY > ANALOG; check if the TEMP value and the HUM value are matched with the environment temperature. When the values are dramatically mismatched (Lager than 15degrees Celsius) 2-1. Check the harness and connector between the DC Controller (UN09/ J206) and the Environment Sensor (UN45) 3-1. Replace the Environment Sensor (UN45) 4-1. Replace the DC Controller (UN9) When the values are matched 2-2. Check the state of the charging high voltage contact point 3-2. Replace the Drum Unit (C) 4-2. Check the harness and connector between the DC Controller PCB (UN09/ J21) and the Primary Charging High Voltage PCB (UN06/ J441, J442) 5-2. Replace the Primary Charging High Voltage PCB (UN06) 6-2. Replace the DC Controller PCB (UN09)
  • Code: E065-0002
  • Description: Error in detection of abnormal C charging AC current value
    During the paper interval simple discharge current control, a current value that is higher than the target of 500[uA] is detected
  • Remedy: Error in output of charging high voltage, Drum Unit error or environment control error 1. COPIER > DISPLAY > ANALOG; check if the TEMP value and the HUM value are matched with the environment temperature. When the values are dramatically mismatched (Lager than 15degrees Celsius) 2-1. Check the harness and connector between the DC Controller (UN09/ J206) and the Environment Sensor (UN45) 3-1. Replace the Environment Sensor (UN45) 4-1. Replace the DC Controller (UN9) When the values are matched 2-2. Check the state of the charging high voltage contact point 3-2. Replace the Drum Unit (C) 4-2. Check the harness and connector between the DC Controller PCB (UN09/ J21) and the Primary Charging High Voltage PCB (UN06/ J441, J442) 5-2. Replace the Primary Charging High Voltage PCB (UN06) 6-2. Replace the DC Controller PCB (UN09)
  • Code: E065-0003
  • Description: Error in detection of abnormal Bk charging AC current value
    During the paper interval simple discharge current control, a current value that is higher than the target of 500[uA] is detected
  • Remedy: Error in output of charging high voltage, Drum Unit error or environment control error 1. COPIER > DISPLAY > ANALOG; check if the TEMP value and the HUM value are matched with the environment temperature. When the values are dramatically mismatched (Lager than 15degrees Celsius) 2-1. Check the harness and connector between the DC Controller (UN09/ J206) and the Environment Sensor (UN45) 3-1. Replace the Environment Sensor (UN45) 4-1. Replace the DC Controller (UN9) When the values are matched 2-2. Check the state of the charging high voltage contact point 3-2. Replace the Drum Unit (Bk). 4-2. Check the harness and connector between the DC Controller PCB (UN09/ J21) and the Primary Charging High Voltage PCB (UN06/ J441, J442) 5-2. Replace the Primary Charging High Voltage PCB (UN06) 6-2. Replace the DC Controller PCB (UN09)