Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR Advance C2025i — Trang 25/45

Code: E355

Description: System error
Remedy: Contact the service company office

Code: E400-0001

Description: Communication error between Reader Controller PCB and DF Unit
Communication checksum error between Reader Controller PCB and DF Unit
Remedy: 1. Turn OFF and then ON the power. 2. Check the connection between Reader Controller PCB and DF Driver PCB (Signal Cable and Power Supply Cable), and check that the Cables are not open-circuit. 3. Replace the Cable between Reader Controller PCB and DF Driver PCB. 4. Replace the Reader Controller PCB. 5. Replace the DF Driver PCB.

Code: E400-0002

Description: Communication error between Reader Controller PCB and DF Unit
Remedy: 1. Turn OFF and then ON the power. 2. Check the connection between Reader Controller PCB and DF Driver PCB (Signal Cable and Power Supply Cable), and check that the Cables are not open-circuit. 3. Replace the Cable between Reader Controller PCB and DF Driver PCB. 4. Replace the Reader Controller PCB. 5. Replace the DF Driver PCB.

Code: E400-0003

Description: Disconnection of the Flat Cable between the Reader Controller PCB and DF Driver PCB
Connection of the Flat Cable between the Reader Controller PCB and DF Driver PCB could not be detected.
Remedy: 1. Turn OFF and then ON the power. 2. Check the connection between Reader Controller PCB and DF Driver PCB (Signal Cable and Power Supply Cable), and check that the Cables are not open-circuit. 3. Replace the cable between Reader Controller PCB and DF Driver PCB. 4. Replace the Reader Controller PCB. 5. Replace the DF PCB.

Code: E413-0001

Description: Release Motor error
Release motor HP sensor open.
Remedy: 1.Replace the Release Motor HP sensor(SR11). 2.Replace the Release Motor(M2). 3.Replace the ADF Driver PCB(PCB1).

Code: E413-0002

Description: Release Motor error
Release motor HP sensor close.
Remedy: 1.Replace the Release Motor HP sensor(SR11). 2.Replace the Release Motor(M2). 3.Replace the ADF Driver PCB(PCB1).

Code: E500-0000

Description: Communication error
The communication with the host machine is interrupted.
Remedy: 1. Replace the finisher controller PCB. 2. Replace the host machine DC Controller PCB.

Code: E503-0002

Description: Communication error
Communication between the Saddle Controller and the Finisher Controller is suspended.
Remedy: 1. The wiring between the finisher controller PCB and saddle controller PCB is faulty. 2. The finisher controller PCB is faulty. 3. The saddle stitcher controller PCB is faulty.