Description: Image process device error
PRIO overrun
Remedy: 1. Turn OFF and then ON the main power 2. Check connection of Main Controller PCB 2 3. Replace Main Controller PCB 2
Code: E315-0500
Description: Device timeout
An image synchronous signal from the Main Controller PCB 2 to the Reader is not received within 30 seconds.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Main Controller PCB 2 (including the flat cable). 3. Replace the flat cable. 4. Replace the Main Controller PCB 2.
Code: E315-0501
Description: Device abnormal completion
An abnormal signal from the Main Controller PCB 2 to the Reader is detected.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Main Controller PCB 2 (including the flat cable). 3. Replace the flat cable. 4. Replace the Main Controller PCB 2.
Code: E315-0510
Description: Device timeout
An image synchronous signal from the Main Controller PCB 2 to the Reader is not received within 30 seconds.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Main Controller PCB 2 (including the flat cable). 3. Replace the flat cable. 4. Replace the Main Controller PCB 2.
Code: E315-0511
Description: Device abnormal completion
An abnormal signal from the Main Controller PCB 2 to the Reader is detected.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Main Controller PCB 2 (including the flat cable). 3. Replace the flat cable. 4. Replace the Main Controller PCB 2.
Code: E315-0520
Description: Device timeout
An image synchronous signal from the Main Controller PCB 2 to the Reader is not received within 30 seconds.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Main Controller PCB 2 (including the flat cable). 3. Replace the flat cable. 4. Replace the Main Controller PCB 2.
Code: E315-0521
Description: Device abnormal completion
An abnormal signal from the Main Controller PCB 2 to the Reader is detected.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Main Controller PCB 2 (including the flat cable). 3. Replace the flat cable. 4. Replace the Main Controller PCB 2.
Code: E315-0530
Description: Device timeout
An image synchronous signal from the Main Controller PCB 2 to the Reader is not received within 30 seconds.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Main Controller PCB 2 (including the flat cable). 3. Replace the flat cable. 4. Replace the Main Controller PCB 2.