Description: Detection of abnormal temperature increase
Fixing Assembly error, Fixing temperature detection error
Remedy: 1. Check the location for voltage of the Fixing Assembly -> Replace with a correct Fixing Assembly for the location in the case of mismatching. 2. Check the location for voltage of the AC Driver PCB (UN14) -> Replace with a correct AC Driver PCB (UN14) for the location in the case of mismatching. 3. Check failure between the AC Driver PCB (UN14/J103) and the Fixing Assembly (UN37/J123, UN13/J13). (trapped cable, open circuit, connector disconnection) -> Replace the part in the case of trapped cable/open circuit 4. Replace the AC Driver PCB (UN14) 5. Replace the Fixing Assembly 6. Replace the DC Controller PCB (UN09) NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
Description: Thermistor open circuit detection
In the period from initial rotation to printing, Main Thermistor 1 detected a temperature of 22 deg C or lower for more than 5 seconds.
Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Replace the Fixing Assembly 3. Replace the DC Controller PCB (UN09) NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
Description: Thermistor open circuit detection
In the period from initial rotation to printing, Main Thermistor 2 detected a temperature of 40 deg C or lower for more than 3 seconds.
Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Replace the Fixing Assembly 3. Replace the DC Controller PCB (UN09) NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
Description: Thermistor open circuit detection
In the period from initial rotation to printing, Sub Thermistor 1 detected a temperature of 40 deg C or lower for more than 3 seconds.
Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Replace the Fixing Assembly 3. Replace the DC Controller PCB (UN09) NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
Description: Thermistor open circuit detection
In the period from initial rotation to printing, Sub Thermistor 2 detected a temperature of 40 deg C or lower for more than 3 seconds.
Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Replace the Fixing Assembly 3. Replace the DC Controller PCB (UN09) NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
Description: Main Thermistor 2 low temperature detection at printing
In the period from printing to last rotation, Main Thermistor 1 detected a temperature of 70 deg C or lower for more than 5 seconds.
Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Replace the Fixing Assembly 3. Replace the DC Controller PCB (UN09) NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
Description: Center Thermistor low temperature detection at printing
In the period from printing to last rotation, Main Thermistor 2 detected a temperature of 80 deg C or lower for more than 1 second.
Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Replace the Fixing Assembly 3. Replace the DC Controller PCB (UN09) NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
Description: Edge Thermistor low temperature detection at printing
In the period from printing to last rotation, Sub Thermistor 1 detected a temperature of 80 deg C or lower for more than 1 second.
Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Replace the Fixing Assembly 3. Replace the DC Controller PCB (UN09) NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.