Description: Communication data error
Connection error between the DC Controller PCB and Main Controller PCB 2, or error in Main Controller PCB 2.
Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
Description: Communication data error
60 sec while waiting for a pickup request
Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
Description: Communication data error
60 sec while waiting for an image output request
Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
Description: Communication data error
After a paper jam, 60 sec has passed without stopping
Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
Description: Communication data error
60 sec has passed while waiting for completion of the initial rotation
Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.