Description: Duplex Cooling Fan error
The Duplex Cooling Fan in the Right Cover rotated for more than the specified period of time after the stop of drive.
Remedy: [Related parts] - Harnesses from the DC Controller PCB to the Duplex Cooling Fan 1. DC Controller PCB (UN04/J122) to Relay Connector (17P) (Unit of replacement: 2ST TRANS. H.V. CONTACT ASS’Y) 2. Relay Connector (17P) to Relay Connector (3P) (Unit of replacement: CABLE, DOOR, RIGHT) 3. Relay Connector (3P) to Relay Connector (3P) (Unit of replacement: CABLE, DOOR FAN, RIGHT) 4. Relay Connector (3P) to Duplex Cooling Fan (FM04) - Duplex Cooling Fan (FM04) - DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Remedy] Check/replace the related parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Zero cross signal detection error
An electrical trouble caused by zero cross signal error. Frequency between 43 Hz and 57 Hz could not be detected for 5000 msec or longer.
Remedy: [Related parts] - Harness between the Low-voltage Power Supply PCB (UN01/J322) and the DC Controller PCB (UN04/J22) (Unit of replacement: CABLE, POWER SUPPLY) - Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) - DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Remedy] Check/replace the related parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Controller Cooling Fan error
It was detected that the Controller Cooling Fan was locked.
Remedy: [Related parts] - Main Controller Cooling Fan (UN81/J15) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) - Main Controller PCB (UN81) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Remedy] Check/replace the related parts.
Description: Board over heat error
Abnormal temperature of CPU on the Main Controller PCB was detected.
Remedy: [Related parts] Main Controller PCB (UN81) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. a. If the error occurred during a service visit and then occurred again, replace the Main Controller PCB. b. If the error does not occur during a service visit but is found in the log: 1. Clean the inlet on the side where the fan is installed and remove dust. 2. Remove dust from the fan in the Controller Box. 3. If the space on the side where the fan is installed is less than 10 cm, ask the customer to secure enough space.
Description: Error for collecting sequence jam log (ADF)
Remedy: [Remedy] Collect debug log and contact to the sales company. [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-R” to “0” (default), it is handled as a jam, instead of an error.
Description: Error for collecting sequence jam log (Printer)
Remedy: [Remedy] Collect debug log and contact to the sales company. [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error.
Description: Error for collecting sequence jam log (Printer)
Remedy: [Remedy] Collect debug log and contact to the sales company. [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error
Description: Error for collecting sequence jam log (Printer)
Remedy: [Remedy] Collect debug log and contact to the sales company. [Reference] By setting “COPIER (LEVEL2)> OPTION> FNCSW> JM-ERR-D” to “0” (default), it is handled as a jam, instead of an error.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.