- Code: E315-0530
- Description: Device timeout error
An image synchronous signal from the Main Controller PCB to the Reader could not be detected for 30 sec or longer.
- Remedy: [Remedy] Replace the Main Controller PCB (UN81). (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)
- Code: E315-0531
- Description: Image processing device error
An abnormal signal from the Main Controller PCB to the Reader was detected.
- Remedy: [Remedy] Replace the Main Controller PCB (UN81). (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)
- Code: E315-0540
- Description: Device timeout error
An image synchronous signal from the Main Controller PCB to the Reader could not be detected for 30 sec or longer
- Remedy: Remedy] Replace the Main Controller PCB (UN81). (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)
- Code: E315-0541
- Description: Image processing device error
An abnormal signal from the Main Controller PCB to the Reader was detected.
- Remedy: [Remedy] Replace the Main Controller PCB (UN81). (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)
- Code: E315-0550
- Description: Device timeout error
An image synchronous signal from the Main Controller PCB to the Reader could not be detected for 30 sec or longer.
- Remedy: [Remedy] Replace the Main Controller PCB (UN81). (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)
- Code: E315-0551
- Description: Image processing device error
An abnormal signal from the Main Controller PCB to the Reader was detected.
- Remedy: [Remedy] Replace the Main Controller PCB (UN81). (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)
- Code: E350
- Description: System error
- Remedy: Contact to the sales company
- Code: E351-0000
- Description: Main Controller PCB communication error
Communication function of the Main Controller PCB did not work properly.