Description: Power supply (24V) error
24V port error when a job is started
Remedy: 1. Turn OFF and then ON the power. 2. Check the connection between Reader and Printer, and check that the Cable is not open-circuit. 3. Check the 24V port of the Reader Controller PCB and DF Driver PCB. 4. Check the power supply and Relay PCB on the Printer side. 5. Replace the Reader Controller PCB and DF Driver PCB.
Description: Power supply (24V) error
24V port error when a job is ended
Remedy: 1. Turn OFF and then ON the power. 2. Check the connection between Reader and Printer, and check that the Cable is not open-circuit. 3. Check the 24V port of the Reader Controller PCB and DF Driver PCB. 4. Check the power supply and Relay PCB on the Printer side. 5. Replace the Reader Controller PCB and DF Driver PCB.
Description: Power supply (24V) error
24V port error when loading
Remedy: 1. Turn OFF and then ON the power. 2. Check the connection between Reader and Printer, and check that the Cable is not open-circuit. 3. Check the 24V port of the Reader Controller PCB and DF Driver PCB. 4. Check the power supply and Relay PCB on the Printer side. 5. Replace the Reader Controller PCB and DF Driver PCB.
Description: Power supply (24V) error
24V port error when the power of DF Unit is turned ON
Remedy: 1. Turn OFF and then ON the power. 2. Check the connection between Reader and Printer, and check that the Cable is not open-circuit. 3. Check the 24V port of the Reader Controller PCB and DF Driver PCB. 4. Check the power supply and Relay PCB on the Printer side. 5. Replace the Reader Controller PCB and DF Driver PCB.
Description: Power supply (24V) error
24V port error when a job is started in the DF Unit
Remedy: 1. Turn OFF and then ON the power. 2. Check the connection between Reader and Printer, and check that the Cable is not open-circuit. 3. Check the 24V port of the Reader Controller PCB and DF Driver PCB. 4. Check the power supply and Relay PCB on the Printer side. 5. Replace the Reader Controller PCB and DF Driver PCB.
Description: Power supply (24V) error
24V port error when a job is ended in the DF Unit
Remedy: 1. Turn OFF and then ON the power. 2. Check the connection between Reader and Printer, and check that the Cable is not open-circuit. 3. Check the 24V port of the Reader Controller PCB and DF Driver PCB. 4. Check the power supply and Relay PCB on the Printer side. 5. Replace the Reader Controller PCB and DF Driver PCB.
Description: Error in communication data
When communication data error between the controller and DC Controller PCB is detected.
Remedy: Check connection of the connector. Check connection of the Sub PCB in the Controller Box. Check connection and replace the DC Controller PCB (UN1)/Main Controller PCB.
Description: Error in controller communication
No response after 1.5 minutes has passed since the print request from the Main Controller to the DC Controller.
Remedy: Check connection of the connector. Check connection of the Sub PCB in the Controller Box. Check connection and replace the DC Controller PCB (UN1)/Main Controller PCB 1.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.