Description: Abnormal current run to the M Drum
Abnormal current run to the M Drum (small current level or no drum is found)
Remedy: 1. Check installation of the Drum Unit. 2. Check if there is failure in grounding contact at the Drum Unit side (such as loosened screw which secures the plate at the contact point). 3. Check if there is failure in grounding contact with the Drum at Process Unit side. 4. Replace the Drum Unit. 5. Replace the Pre-exposure LED PCB (UN25,UN26).
Description: Abnormal current run to the M Drum
The change in current level for M Drum film thickness detection is too much compared to the previous time.
Remedy: 1. Check with the Host Machine which generates an error to check if a wrong cartridge (which is different from the initialized cartridge) is installed. 2. Check if there is failure in grounding contact at the Drum Unit side (such as loosened screw which secures the plate at the contact point) 3. Check if there is failure in grounding contact with the Drum at Process Unit side. 4. Replace the Drum Unit. 5. Replace the Pre-exposure LED PCB (UN25,UN26).
Description: Abnormal current run to the Y Drum
Abnormal initial current level at the time of initialization of the Y Drum film thickness (large current level)
Remedy: 1. Check installation of the Drum Unit. 2. Check if there is failure in grounding contact at the Drum Unit side (such as loosened screw which secures the plate at the contact point). 3. Check if there is failure in grounding contact with the Drum at the Process Unit side. 4. Forced initialization in Service Mode: COPIER > FUNCTION > DPC > DRMRSETY: execution of the color causing the error. 5. Replace the Drum Unit. 6. Check the primary transfer voltage value (if it’s not appropriate, turn OFF and then ON the main power to forcibly execute the ATVC control).
Description: Abnormal current run to the Y Drum
Abnormal initial current level at the time of initialization of the Y Drum film thickness (small current level)
Remedy: 1. Check installation of the Drum Unit. 2. Check if there is failure in grounding contact at the Drum Unit side (such as loosened screw which secures the plate at the contact point). 3. Check if there is failure in grounding contact with the Drum at Process Unit side. 4. Forced initialization in Service Mode: COPIER > FUNCTION > DPC > DRMRSETY: execution of the color causing the error) 5. Replace the Drum Unit. 6. Replace the Pre-exposure LED PCB (UN23,UN24).
Description: Abnormal current run to the C Drum
Abnormal current run to the C Drum (small current level or no drum is found)
Remedy: 1. Check installation of the Drum Unit. 2. Check if there is failure in grounding contact at the Drum Unit side (such as loosened screw which secures the plate at the contact point). 3. Check if there is failure in grounding contact with the Drum at Process Unit side. 4. Replace the Drum Unit. 5. Replace the Pre-exposure LED PCB (UN27,UN28).
Description: Abnormal current run to the C Drum
The change in current level for C Drum film thickness detection is too much compared to the previous time.
Remedy: 1. Check with the Host Machine which generates an error to check if a wrong cartridge (which is different from the initialized cartridge) is installed. 2. Check if there is failure in grounding contact at the Drum Unit side (such as loosened screw which secures the plate at the contact point) 3. Check if there is failure in grounding contact with the Drum at Process Unit side. 4. Replace the Drum Unit. 5. Replace the Pre-exposure LED PCB (UN27,UN28).
Description: Abnormal current run to the M Drum
Abnormal initial current level at the time of initialization of the M Drum film thickness (large current level)
Remedy: 1. Check installation of the Drum Unit. 2. Check if there is failure in grounding contact at the Drum Unit side (such as loosened screw which secures the plate at the contact point). 3. Check if there is failure in grounding contact with the Drum at the Process Unit side. 4. Forced initialization in Service Mode: COPIER > FUNCTION > DPC > DRMRSETM: execution of the color causing the error. 5. Replace the Drum Unit. 6. Check the primary transfer voltage value (if it’s not appropriate, turn OFF and then ON the main power to forcibly execute the ATVC control).
Description: Abnormal current run to the M Drum
Abnormal initial current level at the time of initialization of the M Drum film thickness (small current level)
Remedy: 1. Check installation of the Drum Unit. 2. Check if there is failure in grounding contact at the Drum Unit side (such as loosened screw which secures the plate at the contact point). 3. Check if there is failure in grounding contact with the Drum at Process Unit side. 4. Forced initialization in Service Mode: COPIER > FUNCTION > DPC > DRMRSETM: execution of the color causing the error) 5. Replace the Drum Unit. 6. Replace the Pre-exposure LED PCB (UN25,UN26).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.