Description: Error in Zero Cross
Zero Cross failed to be detected for 50ms or more while the fixing relay was ON.
Remedy: 1. Replace the AC Driver (UN6). 2. Check the cycle of the input voltage (failure in powerperipheral area of the customer. Ask the customer to perform the power supply work).
Description: Error in shutter for Fixing Edge Cooling Fan (if the HP failed to be detected when the error occurred).
Failed to detect that the fan shutter has moved to the specified position when moving the fan shutter from anywhere other than the HP.
Remedy: 1. Check the harness of the Shutter Motor (M27), the Shutter HP Sensor (PS31) and the Shutter Position Sensor (PS32) (to see if the harness is caught, disconnected or physically removed). 2. Replace the Pickup Feed Driver PCB (UN2). 3. Replace the Shutter Motor, the Shutter HP Sensor or the Shutter Position Sensor.
Description: CPU abnormal temperature rising error
It was detected that CPU was 100 deg C or more.
Remedy: When it is detected that the temperature of the CPU is 100 deg C or more, forcible shutdown is executed. After that, the error is recorded in the error log. If the error occurred during a service visit and then occurred again: Replace the Main Controller PCB 1. - If the error does not occur during a service visit but is found in the log: 1. Check the space behind the host machine. If the space behind the host machine is less than 10 cm, ask the user to secure enough space. 2. Clean the inlet on the rear of the host machine. Remove dust.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.