Mã lỗi Canon iR Advance C5045i — Trang 21/56

Code: E110-0300

Description: Error in Polygon Motor of CBk-side Scanner (BD lock failed)
In the case of failure in detecting FG signal although the specified period of time has passed after the Scanner Motor of Laser Scanner Unit 2 (CBk laser) was started.
Remedy: 1. Check the connector of Laser Scanner Unit 2. 2. Replace Laser Scanner Unit 2.

Code: E110-0301

Description: Error in Polygon Motor of CBk-side Scanner (unreached speed)
In the case of failure in detecting FG signal while the Scanner Motor of Laser Scanner Unit 2 (CBk laser).
Remedy: 1. Turn OFF and then ON the power. 2. Check the connector of Laser Scanner Unit 2. 3. Replace Laser Scanner Unit 2.

Code: E112-0000

Description: Error in Dustproof Shutter
Failed to be at HP when it’s open (when the Job is started).
Remedy: 1. Check installation of the Dustproof Shutter Drive. 2. Check if the connector of the Laser Shutter Sensor (PS29) or the Laser Shutter Motor (M28) is removed (disconnected). 3. Check the status of Sensor Flag. 4. Replace the HP Sensor, Replace the Laser Shutter Motor (M28).

Code: E112-0001

Description: Error in Dustproof Shutter
Failure to be back to the HP although the specified period of time has passed when closing.
Remedy: 1. Check installation of the Dustproof Shutter Drive. 2. Check if the connector of the Laser Shutter Sensor (PS29) or the Laser Shutter Motor (M28) is removed (disconnected). 3. Check the status of Sensor Flag. 4. Replace the HP Sensor, Replace the Laser Shutter Motor (M28).

Code: E112-0002

Description: Error in Dustproof Shutter
Failed to move from the HP when opening (the Job is started)
Remedy: 1. Check installation of the Dustproof Shutter Drive. 2. Check if the connector of the Laser Shutter Sensor (PS29) or the Laser Shutter Motor (M28) is removed (disconnected). 3. Check the status of Sensor Flag. 4. Replace the HP Sensor, Replace the Laser Shutter Motor (M28).

Code: E193-0001

Description: Error in IMG2
Failure of LSI timing adjustment circuit on the DC Controller PCB.
Remedy: 1. Turn OFF and then ON the power. 2. Replace the DC Controller PCB (UN2).

Code: E197-0000

Description: Error in communication of HOB DMA mode
Communication failure between CPU and LSI on the DC Controller.
Remedy: 1. Turn OFF and then ON the power. 2. Replace the DC Controller PCB (UN1).

Code: E197-0001

Description: Error in communication of HOB single-shot mode
Communication failure between CPU and LSI on the DC Controller PCB (UN1).
Remedy: 1. Turn OFF and then ON the power. 2. Replace the DC Controller PCB (UN1).