Các lỗi thường gặp

Code :
  • Code: E197-0002
  • Description: Error in communication of HOB single-shot mode
    Communication failure between CPU and LSI on the DC Controller PCB (UN1).
  • Remedy: 1. Turn OFF and then ON the power. 2. Replace the DC Controller PCB (UN1).
  • Code: E197-0003
  • Description: Timeout error in HOB single-shot mode
    Communication failure between CPU and LSI on the DC Controller PCB (UN1).
  • Remedy: 1. Turn OFF and then ON the power. 2. Replace the DC Controller PCB (UN1).
  • Code: E197-0080
  • Description: Timeout error in EHOB transmission-waiting
    Communication failure between the DC Controller PCB (UN1) and Laser Scanner Unit.
  • Remedy: 1. Turn OFF and then ON the power. 2. Check connection of harness on the target color side (YM/CK). 3. Replace the DC Controller PCB (UN1). 4. Replace the Laser Scanner Unit. 5. Replace the harness on the target color side (YM/CK).
  • Code: E197-0081
  • Description: Timeout error in EHOB reception-waiting
    Communication failure between the DC Controller PCB (UN1) and Laser Scanner Unit.
  • Remedy: 1. Turn OFF and then ON the power. 2. Check connection of harness on the target color side (YM/CK). 3. Replace the DC Controller PCB (UN1). 4. Replace the Laser Scanner Unit. 5. Replace the harness on the target color side (YM/CK).
  • Code: E197-00A0
  • Description: Timeout error in HOB transmission-waiting
    Communication failure between CPU and LSI on the DC Controller PCB (UN1).
  • Remedy: 1. Turn OFF and then ON the power. 2. Replace the DC Controller PCB (UN1).
  • Code: E197-00B0
  • Description: Timeout error in HOB reception-waiting
    Communication failure between CPU and LSI on the DC Controller PCB (UN1).
  • Remedy: 1. Turn OFF and then ON the power. 2. Replace the DC Controller PCB (UN1).
  • Code: E197-00E0
  • Description: Timeout error in the Motor stop signal interruption reception
    Communication error between CPU and LSI on the DC Controller PCB
  • Remedy: 1. Turn OFF and then ON the power. 2. Replace the DC Controller PCB (UN1).
  • Code: E197-0100
  • Description: Error in communication of HOB DMA mode
    Communication failure between CPU and LSI on the DC Controller.
  • Remedy: 1. Turn OFF and then ON the power. 2. Replace the DC Controller PCB (UN1).
‹ First  < 19 20 21 22 23 24 25 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục