Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR Advance C5240 — Trang 46/56

Code: E713-0008

Description: Error in IPC communication
When checksum of the received data is not correct.
Remedy: Check the connector connected to the Finisher.

Code: E713-0010

Description: Error in UFDI communication
Neither ACK nor NAK is returned for specified times in a row.
Remedy: Check the connector connected to the Finisher.

Code: E713-0011

Description: Error in UFDI communication
NAK is returned for specified times in a row.
Remedy: Check the connector connected to the Finisher.

Code: E713-0020

Description: UFDI communication error
BCC of the reception data is invalid for specified number of times in a row.
Remedy: Check the connection of the Connector with Finisher.

Code: E713-0021

Description: Error in UFDI communication
Timeout before the completion of reception for specified times in a row.
Remedy: Check the connector connected to the Finisher.

Code: E713-0022

Description: Error in UFDI communication
Undefined error for specified times in a row at reception.
Remedy: Check the connector connected to the Finisher.

Code: E719-0001

Description: Error in Coin Vendor.
Error in starting of the CoinVendor - The Coin Vendor, which should have been connected before the power was turned OFF, is not connected when the power is turned ON.
Remedy: Check the connection between charging management equipment and machine, and check that the Cable is not open-circuit. Clear the error while the charging management equipment is connected to operate and when switching to the operation without charging management equipment. (To prevent the misuse by removing the charging management equipment, this error code is displayed.)

Code: E719-0002

Description: Error in Coin Vendor.
Error in IPC when CoinVendor is running. - In the case of disconnection of IPC or an error in which IPC communication failed to be recovered. - When disconnection of the pickup delivery signal is detected. - When illegal connection is detected (short-circuit with Tx and Rx of IPC)
Remedy: Check the connection between charging management equipment and machine, and check that the Cable is not open-circuit. Clear the error while the charging management equipment is connected to operate and when switching to the operation without charging management equipment. (To prevent the misuse by removing the charging management equipment, this error code is displayed.)