Code :
  • Code: 002-0002-05
  • Description: Fixing Thermistor temperature increase detection error
  • Causes: Startup control was not completed although 60 sec had passed.
  • Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: 002-0003-05
  • Description: Fixing Thermistor temperature increase detection error
  • Causes: After the Fixing Heater was turned ON, the Fixing Main Thermistor detected error in temperature increase.
  • Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: 002-0004-05
  • Description: Fixing Thermistor temperature increase detection error
  • Causes: After the Fixing Heater was turned ON, the Fixing Thermistor (Front) detected error in temperature increase.
  • Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: 002-0005-05
  • Description: Fixing Thermistor temperature increase detection error
  • Causes: After the Fixing Heater was turned ON, the Fixing Thermistor (Rear) detected error in temperature increase.
  • Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: 002-0006-05
  • Description: Fixing Thermistor temperature increase detection error
  • Causes: The Fixing Film Thermistor (Middle) detected no temperature increase.
  • Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: 002-0007-05
  • Description: Fixing Thermistor temperature increase detection error
  • Causes: The Fixing Film Thermistor (Front) detected no temperature increase.
  • Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Sub Thermistor (TH2/J6491) - Sub Thermistor (TH2) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: 002-0008-05
  • Description: Fixing Thermistor temperature increase detection error
  • Causes: The Fixing Film Thermistor (Rear) detected no temperature increase.
  • Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Sub Thermistor (TH2/J6491) - Sub Thermistor (TH2) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: 002-0009-05
  • Description: Fixing Thermistor temperature increase detection error
  • Causes: The Fixing Film Thermistor (Middle) detected error in temperature increase.
  • Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES