Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Main Thermistor detected a high temperature error.
Remedy: [Related parts] R1.00 - Harness connecting from the Feed/Drum Driver PCB (UN2/J213) to the Fixing Cooling Fan (Front) and (Rear) (FM5/J6068 and FM6/J6069) - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Fixing Cooling Fan (Front) (FM5) - Fixing Cooling Fan (Rear) (FM6) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - Feed/Drum Driver PCB (UN2) - DC Controller PCB (UN1) [Remedy] - Check COPIER> DISPLAY> ANALOG> FIX-E. a. In the case of below 283 deg C, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. b. In the case of 283 deg C or higher, check/replace the related harness/cable, connector and parts. [CAUTION] Do not turn ON the power before replacing the Fixing Film Unit. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Thermistor (Front) detected a high temperature error.
Remedy: [Related parts] R1.00 - Harness connecting from the Feed/Drum Driver PCB (UN2/J213) to the Fixing Cooling Fan (Front) and (Rear) (FM5/J6068 and FM6/J6069) - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Fixing Cooling Fan (Front) (FM5) - Fixing Cooling Fan (Rear) (FM6) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - Feed/Drum Driver PCB (UN2) - DC Controller PCB (UN1) [Remedy] - Check COPIER> DISPLAY> ANALOG> FIX-E2. a. In the case of below 295 deg C, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. b. In the case of 295 deg C or higher, check/replace the related harness/cable, connector and parts. [CAUTION] Do not turn ON the power before replacing the Fixing Film Unit. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Thermistor (Rear) detected a high temperature error.
Remedy: [Related parts] R1.00 - Harness connecting from the Feed/Drum Driver PCB (UN2/J213) to the Fixing Cooling Fan (Front) and (Rear) (FM5/J6068 and FM6/J6069) - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Fixing Cooling Fan (Front) (FM5) - Fixing Cooling Fan (Rear) (FM6) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - Feed/Drum Driver PCB (UN2) - DC Controller PCB (UN1) [Remedy] - Check COPIER> DISPLAY> ANALOG> FIX-E3. a. In the case of below 295 deg C, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. b. In the case of 295 deg C or higher, check/replace the related harness/cable, connector and parts. [CAUTION] Do not turn ON the power before replacing the Fixing Film Unit. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Film Thermistor (Middle) detected a high temperature error.
Remedy: [Related parts] R1.00 - Harness connecting from the Feed/Drum Driver PCB (UN2/J213) to the Fixing Cooling Fan (Front) and (Rear) (FM5/J6068 and FM6/J6069) - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Fixing Cooling Fan (Front) (FM5) - Fixing Cooling Fan (Rear) (FM6) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - Feed/Drum Driver PCB (UN2) - DC Controller PCB (UN1) [Remedy] - Check COPIER> DISPLAY> ANALOG> FIX-C. a. In the case of below 260 deg C, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. b. In the case of 260 deg C or higher, check/replace the related harness/cable, connector and parts. [CAUTION] Do not turn ON the power before replacing the Fixing Film Unit. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Film Thermistor (Front) detected a high temperature error.
Remedy: [Related parts] R1.00 - Harness connecting from the Feed/Drum Driver PCB (UN2/J213) to the Fixing Cooling Fan (Front) and (Rear) (FM5/J6068 and FM6/J6069) - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Sub Thermistor (TH2/J6491) - Fixing Cooling Fan (Front) (FM5) - Fixing Cooling Fan (Rear) (FM6) - Sub Thermistor (TH2) - Film Assembly - Fan Shutter - Feed/Drum Driver PCB (UN2) - DC Controller PCB (UN1) [Remedy] - Check COPIER> DISPLAY> ANALOG> FIX-F. a. In the case of below 275 deg C, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. b. In the case of 275 deg C or higher, check/replace the related harness/cable, connector and parts. [CAUTION] Do not turn ON the power before replacing the Fixing Film Unit. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Film Thermistor (Rear) detected a high temperature error.
Remedy: [Related parts] R1.00 - Harness connecting from the Feed/Drum Driver PCB (UN2/J213) to the Fixing Cooling Fan (Front) and (Rear) (FM5/J6068 and FM6/J6069) - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Sub Thermistor (TH2/J6491) - Fixing Cooling Fan (Front) (FM5) - Fixing Cooling Fan (Rear) (FM6) - Sub Thermistor (TH2) - Film Assembly - Fan Shutter - Feed/Drum Driver PCB (UN2) - DC Controller PCB (UN1) [Remedy] - Check COPIER> DISPLAY> ANALOG> FIX-R. a. In the case of below 275 deg C, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. b. In the case of 275 deg C or higher, check/replace the related harness/cable, connector and parts. [CAUTION] Do not turn ON the power before replacing the Fixing Film Unit. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Thermistor detected a high temperature error by hardware detection.
Remedy: [Related parts] R1.00 - Harness connecting from the Feed/Drum Driver PCB (UN2/J213) to the Fixing Cooling Fan (Front) and (Rear) (FM5/J6068 and FM6/J6069) - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Fixing Thermistors (TH2/J6491 and TH1/J6492) - Fixing Cooling Fan (Front) (FM5) - Fixing Cooling Fan (Rear) (FM6) - Fixing Thermistors (TH1 and TH2) - Film Assembly - Fan Shutter - Feed/Drum Driver PCB (UN2) - DC Controller PCB (UN1) [Remedy] - Check the detected temperatures of all the Fixing Thermistors. a. If it is the upper limit temperature or lower, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. b. If it exceeds the upper limit temperature, check/replace the related harness/cable, connector and parts. [CAUTION] Do not turn ON the power before replacing the Fixing Film Unit. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Fixing Thermistor temperature increase detection error
Causes: After the Fixing Heater was turned ON, the Fixing Main Thermistor detected no temperature increase.
Remedy: [Related parts] R1.01 - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Harnesses connecting the AC Driver PCB (UN6/J502),the Drawer Unit (J5012) and the Fixing Heater (J5007) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.