Causes: The Reader Controller PCB did not detect 24 V when the main power was turned ON.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN_BO1/J104) and the DADF Driver PCB (PCB1/ J402) - Harness between the Reader Controller PCB (UN_BO1/J4) and the Relay PCB (UN5/J407) - Harness between the Relay PCB (UN5/J405) and the 24V Power Supply PCB (UN10/J834) - Reader Controller PCB (UN_BO1) - DADF Driver PCB (PCB1) - Relay PCB (UN5) - 24V Power Supply PCB (UN10) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - When an error is detected, conduction of 24 V is stopped. At power check, check if 24 V is conducted or rated voltage is output by repeating power cycling of the machine. - Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Causes: The DADF Driver PCB did not detect 24 V when the main power was turned ON.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN_BO1/J104) and the DADF Driver PCB (PCB1/ J402) - Harness between the Reader Controller PCB (UN_BO1/J4) and the Relay PCB (UN5/J407) - Harness between the Relay PCB (UN5/J405) and the 24V Power Supply PCB (UN10/J834) - Reader Controller PCB (UN_BO1) - DADF Driver PCB (PCB1) - Relay PCB (UN5) - 24V Power Supply PCB (UN10) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - When an error is detected, conduction of 24 V is stopped. At power check, check if 24 V is conducted or rated voltage is output by repeating power cycling of the machine. - Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Causes: A communication error occurred between the Main Controller PCB and the DC Controller PCB.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN1/J100 and J101) and the Riser PCB (J2 and J10) - Connector between the Main Controller PCB and the Riser PCB - Riser PCB - Main Controller PCB - DC Controller PCB (UN1) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Causes: The Main Controller PCB detected reading error of the Reader backup value in the Reader Controller PCB.
Remedy: Check/replace the Reader Controller PCB (PCB1). [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Causes: The Main Controller PCB failed writing of the Reader backup value in the Reader Controller PCB.
Remedy: Check/replace the Reader Controller PCB (PCB1). [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Causes: The Main Controller PCB detected an error at inspection after completion of writing of the Reader backup value in the Reader Controller PCB.
Remedy: Check/replace the Reader Controller PCB (PCB1). [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.