Description: Fixing Thermistor temperature increase detection error
Causes: The Fixing Film Thermistor (Front) detected error in temperature increase.
Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Sub Thermistor (TH2/J6491) - Sub Thermistor (TH2) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: 002-0011-05
Description: Fixing Thermistor temperature increase detection error
Causes: The Fixing Film Thermistor (Rear) detected error in temperature increase.
Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Sub Thermistor (TH2/J6491) - Sub Thermistor (TH2) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: 003-0001-05
Description: Fixing Thermistor low temperature detection error
Causes: The Fixing Main Thermistor detected an abnormally low temperature during print control.
Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: 003-0002-05
Description: Fixing Thermistor low temperature detection error
Causes: The Fixing Sub Thermistor (Front) detected an abnormally low temperature during print control.
Remedy: - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: 003-0003-05
Description: Fixing Thermistor low temperature detection error
Causes: The Fixing Sub Thermistor (Rear) detected an abnormally low temperature during print control.
Remedy: - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: 003-0004-05
Description: Fixing Thermistor low temperature detection error
Causes: The Fixing Film Thermistor (Middle) detected an abnormally low temperature during print control.
Remedy: - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Main Thermistor (TH1/J6492) - Main Thermistor (TH1) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: 003-0005-05
Description: Fixing Thermistor low temperature detection error
Causes: The Fixing Film Thermistor (Front) detected an abnormally low temperature during print control.
Remedy: - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Sub Thermistor (TH2/J6491) - Sub Thermistor (TH2) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: 003-0006-05
Description: Fixing Thermistor low temperature detection error
Causes: The Fixing Film Thermistor (Rear) detected an abnormally low temperature during print control.
Remedy: - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Sub Thermistor (TH2/J6491) - Sub Thermistor (TH2) - Film Assembly - Fan Shutter - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES