  • Code: E717-0002
  • Description: Communication with the NE controller is abnormal. IPC error in the NE controller operation In the case of the errors that disconnection of IPC, or IPC communication is unrecoverable.
  • Remedy: Recover with service mode COPIER>FUNCTION>CLEA R>ERR after cable check
  • Code: E719-0001
  • Description: Coin vendor failure. Error in the Coin vendor start When the Coin vendor which should have been connected is not connected before the power off at power supply time to turn on
  • Remedy: Recover with service mode COPIER>FUNCTION>CLEA R>ERR after cable check
  • Code: E719-0002
  • Description: Coin vendor failure. IPC error in the Coin vendor operation In the case of the errors that disconnection of IPC, or IPC communication is unrecoverable. In the case of connection failure detection for a signal of paper pickup/delivery In the case of the detection of improper connection
  • Remedy: Recover with service mode COPIER>FUNCTION>CLEA R>ERR after cable check
  • Code: E719-0003
  • Description: Coin vendor failure. In the case of communication error with the Coin vendor during the unit price acquisition in startup
  • Remedy: Recover with service mode COPIER>FUNCTION>CLEA R>ERR after cable check
  • Code: E719-0011
  • Description: Error in the card reader startup. When the card reader, which should have been connected before the power off, is not connected at power ON.
  • Remedy: Recover with service mode COPIER>FUNCTION>CLEA R>ERR after cable check
  • Code: E719-0012
  • Description: IPC error in the card reader operation. In the case of the errors that disconnection of IPC, or IPC communication is unrecoverable.
  • Remedy: Recover with service mode COPIER>FUNCTION>CLEA R>ERR after cable check
  • Code: E719-0031
  • Description: Communication error in the card reader (a serial number) startup. In case a communication with card reader cannot start in startup
  • Remedy: 1. Recover with service mode COPIER>FUNCTION>CLE AR>ERR after cable connection check for card reader (Connector connection, pinching wire) 2. Execute the following service mode after card reader removal, and re-install card reader. * COPIER>FUNCTION>CLEAR>CARD * COPIER>FUNCTION>CLEAR>ERR
  • Code: E719-0032
  • Description: Communication error after the card reader (a serial number) startup. Communicate with card reader is succeeded in the startup, but it became impossible.
  • Remedy: Recover with service mode COPIER>FUNCTION>CLE AR>ERR after cable connection check for card reader (Connector connection, pinching wire)