Code: E748-2023

Description: Main controller board 2 access errors
Remedy: DDR2-SDRAM (M0/M1/P) removing and inserting, replacement

Code: E748-2024

Description: Main controller board 2 access errors
Remedy: Main controller board 1/2 removing and inserting, replacement

Code: E748-2025

Description: Main Controller PCB 2 access error. Disconnection of the Bypass PCB was detected.
Remedy: Remove and then install the Bypass PCB.

Code: E748-2026

Description: Main Controller PCB 2 access error. Disconnection of the Image Processing Sub PCB was detected.
Remedy: Remove and then install the Image Processing Sub PCB.

Code: E748-4xxx

Description: Main controller board 2 errors
Remedy: Main controller board replacement

Code: E748-9000

Description: System error
Remedy: Contact each sale company bases

Code: E749-0006

Description: Restart direction due to configuration change. The option such as the Finisher and Paper Deck was installed or removed when all of following conditions were met and the machine configuration is changed when the main power switch is turned ON. • Settings/Registration > Preferences > Timer/Energy Settings > Quick Startup at Power-on > ON • The Main Power Switch is turned OFF • The power plug of the machine is connected to the output. • The breaker is ON
Remedy: It is recovered by turning OFF and then ON the main power. CAUTION This machine provides power to some PCBs even when in the main power OFF status. The power supply is not completely OFF by just turning OFF the main power switch and therefore, the machine is unable to detect a configuration change. When disconnecting and then connecting a connector, always disconnect the power plug or turn the breaker OFF. Refer to the Service Manual > Chapter 2 > External and Controls > Quick Startup for details.

Code: E753-0001

Description: Error in Finisher Boot software. The Boot software has not been written in ROM of the finisher controller.
Remedy: 1. The finisher controller PCB is faulty. 2. The host machine controller PCB is faulty.