Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR Advance C7260i — Trang 22/75

Code: E064-2201

Description: Primary charging DC bias (M) output error. The primary charging DC bias (M) output showed an abnormal value
Remedy: Replace the Primary Charging High Voltage PCB (Y/M/C).

Code: E064-2203

Description: Developing DC bias (M) output error. The developing DC bias (M) output showed an abnormal value.
Remedy: Replace the Developing High Voltage PCB (Y/M/C).

Code: E064-3301

Description: Primary charging DC bias (C) output error. The primary charging DC bias (C) output showed an abnormal value
Remedy: Replace the Primary Charging High Voltage PCB (Y/M/C).

Code: E064-3303

Description: Developing DC bias (C) output error. The developing DC bias (C) output showed an abnormal value
Remedy: Replace the Developing High Voltage PCB (Y/M/C).

Code: E064-4403

Description: Developing DC bias (Bk) output error. The developing DC bias (Bk) output showed an abnormal value.
Remedy: Replace the Developing High Voltage PCB (Bk).

Code: E066-0001

Description: Pre-transfer Charging Wire Shutter HP open error. The Pre-transfer Charging Wire Shutter HP Sensor (PS93) detected that the shutter was open although it was moved to the close position.
Remedy: 1. Check connection of the Pre-transfer Charging Wire Cleaning Motor (M2). 2. Replace the Pre-transfer Charging Wire Cleaning Motor (M2). 3. Check connection of the Pre-transfer Charging Wire Shutter HP Sensor (PS93). 4. Replace the Pre-transfer Charging Wire Shutter HP Sensor (PS93). 5. Check shutter mechanism of the Pre-transfer Charging Assembly. 6. Replace the Pre-transfer Charging Assembly. 7. Replace the DC Controller PCB.

Code: E066-0002

Description: Pre-transfer Charging Wire Shutter HP close error. The Pre-transfer Charging Wire Shutter HP Sensor (PS93) detected that the shutter was closed although it was moved to the open position
Remedy: 1. Check connection of the Pre-transfer Charging Wire Cleaning Motor (M2). 2. Replace the Pre-transfer Charging Wire Cleaning Motor (M2). 3. Check connection of the Pre-transfer Charging Wire Shutter HP Sensor (PS93). 4. Replace the Pre-transfer Charging Wire Shutter HP Sensor (PS93). 5. Check shutter mechanism of the Pre-transfer Charging Assembly. 6. Replace the Pre-transfer Charging Assembly. 7. Replace the DC Controller PCB.

Code: E066-0011

Description: Primary Charging Wire Shutter error 1 when cleaning the Pre-transfer Charging Wire. The Pre-transfer Charging Wire Shutter HP Sensor (PS93) failed to be detected although 10 seconds have passed since the Pre-transfer Charging Wire Shutter started its operation
Remedy: 1. Check connection of the Pre-transfer Charging Wire Shutter HP Sensor (PS93). 2. Replace the Pre-transfer Charging Wire Shutter HP Sensor (PS93). 3. Check shutter mechanism of the Pre-transfer Charging Assembly. 4. Replace the Pre-transfer Charging Assembly. 5. Replace the DC Controller PCB.