Description: Abnormal Temperature Rise of Fixing Edge Front Thermistor (THM2). The Fixing Edge Front Thermistor (THM2) detected abnormal high temperature (software detection)
Remedy: Check the detected temperature of the Fixing Edge Front Thermistor (THM2) in service mode (COPIER > DISPLAY > ANALOG > FIX-UE2) A. When the detected temperature was 260 deg C or higher A-1. Cable of the Fixing Edge Front Thermistor is caught. -> Replace the Fixing Film Unit. B. When the detected temperature was lower than 260 deg C B-1. The Fixing Main Thermistor is not securely attached. -> Replace the Fixing Film Unit. B-2. Replace the DC Controller PCB. NOTE: After performing the remedy work above, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
Code: E003-0001
Description: Fixing Film abnormally low temperature. After standby, fixing main thermistor (THM1) detected less or equal to 110 degrees Celsius in succession for 1 second.
Remedy: 1. Check the rear louver. (If the rear of the machine is close to the wall, temperature of the power supply area may rise) 2. Check the detection temperature of the thermistor in service mode (COPIER> DISPLAY> ANALOG> FIXxx). A. In case that either one of the thermistor detection temperature is risen A-1. Check the fixing film unit (to see if the location of the thermistor is inappropriate or the thermistor failure) -> replace the fixing film unit A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing drawer cable B. In case that neither of them are not risen B-1. Check the connection of the fixing thermistor (to see if the connection of the drawer is faulty, the connector is physically removed or disconnected) -> replace the fixing film unit B-2. Check the connection of the IH power connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-3. Replace the IH power unit B-4. Replace the DC controller PCB NOTE: After performing the above remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR
Code: E004-0201
Description: Fixing Film temperature difference error 1. Difference of detected temperature between the fixing subthermistor 2 (THM4) and the fixing subthermistor 1 (THM3) is bigger than the rated value.
Remedy: 1. Fixing main /sub thermistor (THM1-1/2/3) connector disconnetion (pinching wire, broken wire) -> replace the fixing film unit 2. Check the rotation of the fixing motor (to see if the connector is physically removed or disconnected) -> replace the fixing motor or the harness 3. Faulty drawer connector -> clean the drawer connector or replace the fixing drawer cable 4. Replace the DC controller PCB
Code: E004-0202
Description: Fixing Film temperature difference error 2. Difference of detected temperature between the fixing main thermistor (THM1) and the fixing subthermistor 1 (THM3) are bigger than the rated value.
Remedy: 1. Fixing main /sub thermistor (THM1-1/2/3) connector disconnetion (pinching wire, broken wire) -> replace the fixing film unit 2. Check the rotation of the fixing motor (to see if the connector is physically removed or disconnected) -> replace the fixing motor or the harness 3. Faulty drawer connector -> clean the drawer connector or replace the fixing drawer cable 4. Replace the DC controller PCB
Code: E004-0203
Description: Fixing Film temperature difference error 3. Difference of detected temperature between the fixing main thermistor (THM1) and the fixing subthermistor 2 (THM1) are bigger than the rated value.
Remedy: 1. Fixing main /sub thermistor (THM1-1/2/3) connector disconnetion (pinching wire, broken wire) -> replace the fixing film unit 2. Check the rotation of the fixing motor (to see if the connector is physically removed or disconnected) -> replace the fixing motor or the harness 3. Faulty drawer connector -> clean the drawer connector or replace the fixing drawer cable 4. Replace the DC controller PCB
Code: E004-0214
Description: Fixing Film temperature difference error 4. Temperature difference between the Fixing Edge Front Thermistor (THM2) and the Fixing Edge Rear Thermistor (THM5) is 50 deg C or greater
Remedy: 1. Replace the Fixing Film Unit. 2. Replace the Fixing Motor/Harness. 3. Clean the Drawer Connector/Replace the Fixing Drawer Harness. 4. Replace the DC Controller PCB.
Code: E004-0215
Description: Fixing Film displacement error. Temperature difference between the Fixing Edge Front Thermistor (THM2) and the Fixing Edge Rear Thermistor (THM5) was 20 deg C or greater when checking operation of the Fixing Film.
Remedy: Replace the Fixing Film Unit.
Code: E004-0301
Description: IH overcurrent detection error. Detected an overcurrent on IH power supply board.
Remedy: 1. Faulty fixing film unit -> replace the fixing film unit 2. Faulty fixing IH unit -> replace the fixing IH unit 3. Faulty IH power PCB -> replace the IH power PCB