Description: 12V failure error. Detected abnormality on the 12V power supply line.
Remedy: 1. Check the Fixing Film -> Replace the Fixing Film Unit when it is damaged. 2. Check connection of the Fixing Thermoswitch (TP2) (to see if Thermoswitch is being turned OFF/open circuit). -> Replace the Fixing Film Unit. 3. Replace the Relay PCB. 4. Replace the DC Controller PCB. 5. Replace the IH power supply. NOTE: After performing the remedy work above, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
Description: Connection error of Fixing Main Thermistor or Fixing Edge Front Thermistor. Connection detection signal for the Fixing Main Thermistor or Fixing Edge Front Thermistor could not be detected
Remedy: 1. Check connection of the Fixing Film Unit. -> Replace the Fixing Film Unit when it is damaged. 2. Failure in Drawer Connector. -> Clean the Drawer Connector/Replace the Fixing Drawer Harness
Description: Connection error of Fixing Sub Thermistor 1/2 or Fixing Edge Rear Thermistor. Connection detection signal for Fixing Sub Thermistor 1/2 or Fixing Edge Rear Thermistor could not be detected
Remedy: 1. Check connection of the Fixing Film Unit. -> Replace the Fixing Film Unit when it is damaged. 2. Failure in Drawer Connector. -> Clean the Drawer Connector/Replace the Fixing Drawer Harness
Description: Fixing Web level absence error. The count exceeded 60,000 (using A4/Letter size or smaller paper) after the Fixing Web Level Sensor detected absence of the web
Remedy: 1. Check the Fixing Web. 2. When the Fixing Web is replaced, execute the following to clear the counter value: COPIER > COUNTER > DRBL-1 > FX-WEB1 to 4, or COPIER> COUNTER>MISC>FX-WEB. Then, turn OFF and then ON the main power. 3. Check the Sensor Harness. 4. Replace the Web Level Sensor (PS102). 5. Replace the Torsion Spring. 6. Replace the Level Detection Arm. 7. Replace the Web Sensor Support Plate
Description: Fixing Film Unit life detection error. Total rotation time of the Fixing Film reached 5206 hours.
Remedy: 1. Life of the Fixing Film Unit -> Replace the Fixing Film Unit. 2. When the Fixing Film Unit is replaced, turn OFF and then ON the main power after executing the following: COPIER > COUNTER > DRBL-1 > FX-BLT-U.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.