Description: 12V failure error. Detected abnormality on the 12V power supply line.
Remedy: 1. Check the Fixing Film -> Replace the Fixing Film Unit when it is damaged. 2. Check connection of the Fixing Thermoswitch (TP2) (to see if Thermoswitch is being turned OFF/open circuit). -> Replace the Fixing Film Unit. 3. Replace the Relay PCB. 4. Replace the DC Controller PCB. 5. Replace the IH power supply. NOTE: After performing the remedy work above, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
Code: E004-0501
Description: Connection error of Fixing Main Thermistor or Fixing Edge Front Thermistor. Connection detection signal for the Fixing Main Thermistor or Fixing Edge Front Thermistor could not be detected
Remedy: 1. Check connection of the Fixing Film Unit. -> Replace the Fixing Film Unit when it is damaged. 2. Failure in Drawer Connector. -> Clean the Drawer Connector/Replace the Fixing Drawer Harness
Code: E004-0502
Description: Connection error of Fixing Sub Thermistor 1/2 or Fixing Edge Rear Thermistor. Connection detection signal for Fixing Sub Thermistor 1/2 or Fixing Edge Rear Thermistor could not be detected
Remedy: 1. Check connection of the Fixing Film Unit. -> Replace the Fixing Film Unit when it is damaged. 2. Failure in Drawer Connector. -> Clean the Drawer Connector/Replace the Fixing Drawer Harness
Code: E004-0702
Description: IH power supply relay abnormality.Voltage shows abnormal value even with the relay-off
Remedy: IH power supply replacement
Code: E005-0000
Description: Fixing Web level absence error. The count exceeded 60,000 (using A4/Letter size or smaller paper) after the Fixing Web Level Sensor detected absence of the web
Remedy: 1. Check the Fixing Web. 2. When the Fixing Web is replaced, execute the following to clear the counter value: COPIER > COUNTER > DRBL-1 > FX-WEB1 to 4, or COPIER> COUNTER>MISC>FX-WEB. Then, turn OFF and then ON the main power. 3. Check the Sensor Harness. 4. Replace the Web Level Sensor (PS102). 5. Replace the Torsion Spring. 6. Replace the Level Detection Arm. 7. Replace the Web Sensor Support Plate
Description: Fixing Feed drawer connection error. Fixing feed knob of fixing drawer is abnormal (Sensor cannot detect)
Remedy: 1. Fixing feed knob of fixing drawer has connection failure 2. Wire harness failure 3. Sensor failure
Code: E008-0002
Description: Fixing Film Unit life detection error. Total rotation time of the Fixing Film reached 5206 hours.
Remedy: 1. Life of the Fixing Film Unit -> Replace the Fixing Film Unit. 2. When the Fixing Film Unit is replaced, turn OFF and then ON the main power after executing the following: COPIER > COUNTER > DRBL-1 > FX-BLT-U.