Description: Error in the reader type. When a scanner for the different model is detected during the communication with the reader.
Remedy: Replace to the proper reader.
Code: E732-9999
Description: The Reader detection.
Remedy: In case of first detection of the reader on printer model (‘Please power cycle’ message is only displayed on the user screen instead of an error code. Service mode> DISPLAY> ERR is recorded in error log.)
Code: E733-0001
Description: Printer communication is abnormal. Failure of communication between the controller and DC controller
Remedy: 1. Connected connector check with the printer 2. The power supply check (check if initialization is executed in startup) of the printer 3. Replacement of DC controller or main controller board
Code: E733-0002
Description: Printer communication error. An error occurred to detect printer vertical synchronous signal.
Remedy: 1. Check the connection to the printer. ?¨ Connect the connector/replace the harness. 2. Check the power of the printer (check if the initialization operation is executed at startup). 3. Replace the DC Controller PCB/Main Controller PCB.
Code: E733-0010
Description: Printer communication is abnormal. Printer vertical synchronizing signal detection failure
Remedy: 1. Connected connector check with the printer 2. The power supply check (check if initialization is executed in startup) of the printer 3. Replacement of DC controller or main controller board
Code: E733-0020
Description: Printer communication is abnormal. Communication error
Remedy: 1. Connected connector check with the printer 2. The power supply check (check if initialization is executed in startup) of the printer 3. Replacement of DC controller or main controller board
Code: E733-0021
Description: Printer communication is abnormal. Communication error
Remedy: 1. Connected connector check with the printer 2. The power supply check (check if initialization is executed in startup) of the printer 3. Replacement of DC controller or main controller b
Code: E743-0000
Description: DDI communication error. The reader controller PCB detected a failure in communication between the main controller PCB and the reader controller PCB.
Remedy: 1. Failure of the connection between the main controller PCB and the reader controller PCB 2. Failure of the reader controller PCB (PCB1) 3. Failure of the main controller PCB