Causes: VLOCK signal (Y) was not detected during FG rotation of the Laser Scanner Motor.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1200) and the Relay PCB (UN7/J1817) - Harnesses between the DC Controller PCB (UN2/J1259, J1220 and J1221) and the Laser Interface PCB (UN106/J15, J10 and J16) - Harness between the Laser Interface PCB (UN106/J70) and the Laser Scanner Unit (Y) (J8076) - Laser Scanner Unit (Y) - Laser Interface PCB (UN106) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Causes: VLOCK signal (M) was not detected during FG rotation of the Laser Scanner Motor.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1200) and the Relay PCB (UN7/J1817) - Harnesses between the DC Controller PCB (UN2/J1259, J1220 and J1221) and the Laser Interface PCB (UN106/J15, J10 and J16) - Harness between the Laser Interface PCB (UN106/J70) and the Laser Scanner Unit (M) (J8070) - Laser Scanner Unit (M) - Laser Interface PCB (UN106) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Causes: VLOCK signal (C) was not detected during FG rotation of the Laser Scanner Motor.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1200) and the Relay PCB (UN7/J1817) - Harnesses between the DC Controller PCB (UN2/J1259, J1220 and J1221) and the Laser Interface PCB (UN106/J15, J10 and J16) - Harness between the Laser Interface PCB (UN106/J76) and the Laser Scanner Unit (C) (J8066) - Laser Scanner Unit (C) - Laser Interface PCB (UN106) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Causes: VLOCK signal (Bk) was not detected during FG rotation of the Laser Scanner Motor.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1200) and the Relay PCB (UN7/J1817) - Harnesses between the DC Controller PCB (UN2/J1259, J1220 and J1221) and the Laser Interface PCB (UN106/J15, J10 and J16) - Harness between the Laser Interface PCB (UN106/J76) and the Laser Scanner Unit (Bk) (J8064) - Laser Scanner Unit (Bk) - Laser Interface PCB (UN106) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Causes: A communication error between the DC Controller PCB and the Fixing Feed Driver PCB was detected.
Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN2/J1222), the Drawer Unit (J8023) and the Fixing Feed Driver PCB (UN5/J1510) - Fixing Feed Driver PCB (UN5) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Causes: A communication error between the DC Controller PCB and the Multi Deck was detected.
Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN2/J1230,J1231), the Drawer Unit (J8240) and the Multi Deck - Multi Deck - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.