Code: 677-0001-00

Description: Print server error
Causes: Abnormality detected on the exhaust fan operation of printer server
Remedy: 1. Check supplying power to the exhaust fan 2. Exhaust fan replacement

Code: 677-0003-00

Description: Print server error
Causes: An error in the fan of the Print Server was detected.
Remedy: [Related parts] R1.00 - Print Server Fan - Main Controller PCB [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 677-0004-00

Description: Print server error
Causes: Abnormality detected on the CPU fan operation of printer server
Remedy: 1. Check supplying power to the CPU fan 2. CPU fan replacement

Code: 677-0010-00

Description: Print server error
Causes: Failure was detected in operation of the CPU fan on the print server.
Remedy: 1. Replace the board of the print server. 2. Reinstall the Print Server (For details, refer to "Service Manual image PASS P2.")

Code: 677-0080-00

Description: Print server error
Causes: Error is detected at the Mother Board check when print server is started.
Remedy: 1. Check the cable connection and turn OFF and then ON the power. 2. Reinstall the print server (For details, refer to "Service Manual image PASS P2.")

Code: 711-0001-05

Description: Communication error
Causes: An error was detected in IPC communication with the finisher.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1226) and the Finisher Lattice (J7512A) - Finisher Controller PCB - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES - After replacement of the Finisher Controller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual for the Finisher.

Code: 711-0002-05

Description: Communication error
Causes: A block checksum error was detected in IPC communication with the finisher.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1226) and the Finisher Lattice (J7512A) - Finisher Controller PCB - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES - After replacement of the Finisher Controller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual for the Finisher.

Code: 713-0001-05

Description: Communication error
Causes: Reception error was detected 3 consecutive times in communication with the finisher.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1226) and the Finisher Lattice (J7512A) - Finisher Controller PCB - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES - After replacement of the Finisher Controller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual for the Finisher.